43
5
OPTION
43
OPTION
Chapter
5
Select data/stop bit.
Select terminator.
When receiving data or a command through the RS-232C interface, the M252B returns with the
received data or command to the host computer. Select this return format.
Name of setting
48: RS-232C Data/Stop Bit
Selection item
0. 7bit 1stop (initial value)
1. 7bit 2stop
2. 8bit 1stop
3. 8bit 2stop
Caution
The setting must be the same as the connecting equipment.
Name of setting
49: RS-232C Terminator
Selection item
0. CR
1. CR+LF (initial value)
Caution
The setting must be the same as the connecting equipment.
Name of setting
50: RS-232C Answer Mode
Selection item
0. MODE 0 (M250 mode) (initial value)
1. MODE 1 (M252 mode)
Reference
Select the M250 mode when using software specifically prepared for
UNIPULSE-manufactured intelligent printer M250 in the M252B.
Normally, it is recommended to use the M252 mode.
Caution
When preparing software such that two or more commands are sent
successively, be sure to program the software so that the next command is sent
after receiving a response .
48: RS-232C Data/Stop Bit
When printing a
katakana
code, set the RS-232C character length of the M252B
and the PC to 8 bits. If set to 7 bits, transmission of
katakana
data is disabled.
Attention
49: RS-232C Terminator
50: RS-232C Answer Mode