56
7
OPTION (Setting Code 38)
56
OP
TION
Chapter
7
Explanation of remote resistor M
→
R
- Writing data area (32 bit binary)
(0 to 99999)
Use to write set values.
- Code No. (8 bit binary)
(00 to 99)
Set a code No. Be aware that the response flag does not turn on to an invalid command.
The high byte is ignored.
Remote resistor R
→
M (F160
→
PLC)
Explanation of remote resistor R
→
M
- Weight value (32 bit binary)
(-99999 to 99999)
Indicates the weight value. If the data is minus, two’s-complement numbers will result.
- Error code (4bit BCD)
(0 to 9)
Indicates the error code of the controller.
For details, refer to "9-2.Error List" on page 85.
- Error assistance code (4bit BCD)
(0 to 9)
Indicates the error assistance code of the controller.
For details, refer to "9-2.Error List" on page 85.
- Reading out data area (32 bit binary)
(0 to 99999)
Area to read set values.
- Code No. response (8 bit binary)
(00 to 255)
Set a code No. for request ON.
255 is set when the command makes an error and it responds.
Station
Buffer
Device
Description
address
M
→
R
MSB
LSB
1
02E0H
02E1H
RWr0000
RWr0001
L
Indicated value (Net weight/Gross weight)
32bit
H
02E2H
RWr0002
0
Error code
8bit
02E3H
RWr0003
0
Error assistance code
8bit
2
02E4H
02E5H
RWr0004
RWr0005
L
Reading out data area
32bit
H
02E6H
RWr0006
0
Code No. (response)
8bit
02E7H
RWr0007
Unused
16bit
Содержание F160
Страница 1: ...01AUG2017REV 1 06 WEIGHING CONTROLLER F160 CC Link Ver 1 10 OPERATION MANUAL...
Страница 9: ...CONTENTS VIII CONTENTS VIII M E M O...
Страница 84: ...75 8 SPECIFICATIONS 75 SPECIFICATIONS Chapter 8 Equipped with BCD parallel data output interface option Unit mm...
Страница 85: ...76 8 SPECIFICATIONS 76 SPECIFICATIONS Chapter 8 Equipped with CC Link interface option Unit mm...
Страница 99: ......