83
9
SUPPLEMENTS
83
SUPPLEMENTS
Chapter
9
Code
Function
Setting range
30
Digital filter
0000 (OFF), 0002 to 1024 [times]
31
Motion detection (period)
0.0 to 9.9
32
Motion detection (range)
00 to 99
33
Zero tracking (period)
0.0 to 9.9
34
Zero tracking (range)
00 to 99
35
Analog filter
0: 2, 1: 4, 2: 6, 3: 8 [Hz]
36
Filter in a stable condition
0: Insert (256times), 1: Not insert
37
Motion detection mode
0: Stable mode, 1: Checker mode
38
Option setting
No option
0 0 0 0 0
BCD Parallel Data Output Interface
0 3 0 1 0
CC-Link Interface
4 0 1 0 0
39
SI/F G/N selection
0: Gross weight, 1: Net weight
Code
Function
Setting range
40
Balance weight
00000 to 99999
41
Capacity
00000 to 99999
42
Minimum scale division
001 to 100
43
Net over
00000 to 99999
44
Gross over
00000 to 99999
45
Digital zero regulation value
0000 to 9999
46
Decimal place
0: 0, 1: 0.0, 2: 0.00, 3: 0.000
47
Gravitational acceleration
01 to 16
48
Calibration value LOCK
0: Release, 1: LOCK
49
Set value LOCK
0: Release, 1: LOCK
Undefined
Undefined
BCD output data form
0: BCD, 1: Binary
BCD output rate [Times/sec.]
0: 10, 1: 20, 2: 50, 3: 100,
4: 200, 5: 500, 6: 1000
BCD output data selection
0: Gross weight, 1: Net weight,
Output signal selection
0: Near zero, 1: Stable, 2: Weight alarm,
3: Sequence error, 4: Final error,
5: Zero alarm
2: Tare weight, 3: Ext.
Undefined
Station No.
1
to
63
Baud rate [bps]
0: 156k, 1: 625k, 2: 2.5M, 3: 5M, 4: 10M
Содержание F160
Страница 1: ...01AUG2017REV 1 06 WEIGHING CONTROLLER F160 CC Link Ver 1 10 OPERATION MANUAL...
Страница 9: ...CONTENTS VIII CONTENTS VIII M E M O...
Страница 84: ...75 8 SPECIFICATIONS 75 SPECIFICATIONS Chapter 8 Equipped with BCD parallel data output interface option Unit mm...
Страница 85: ...76 8 SPECIFICATIONS 76 SPECIFICATIONS Chapter 8 Equipped with CC Link interface option Unit mm...
Страница 99: ......