16
3
SETTING PROCEDURE
16
SETTING PROCEDURE
Chapter
3
Executing Equivalent Input Calibration (with the rated output value set at 1.0000mV/V and
Balance Weight 25000)
1.
From the indicated value display screen,
set setting mode 9 by pressing
[FNC]
→
[
][
][
][
][
][
][
][
][
].
2.
Select item number 2 with [
△
]/[
▽
].
The item number and set value are displayed.
3.
Enable change with [
], so that the most significant
digit of the set value flashes.
Set "1" with [
△
]/[
▽
].
4.
Determine it with [
], so that equivalent input
calibration is executed.After execution, you will go back
to the gross weight display.
* To cancel the execution, press [FNC] to go back to the
set value display.
▽
▽
▽
▽
▽
▽
▽
▽
▽