CWD2005 DPC
Operation combustion calorimeter
chapter — page:
7—37
7.4 General information on the start screen
Fig. 7.2:
Information field, start screen
Indication (screen)
Information
1
V 4.39R09
Version number of the software
2
04.02.2015 10:05:09
Current date / time
3
Methane: 95.01 Vol%
Volume share of methane
4
mV=24.56
mV signal of the thermal battery
5
V=1.071
Voltage signal of the density measuring cell
6
T1=29.04/0.24
Inlet temperature into the thermal body / heating of the
air
7
p=4.00
Air differential pressure
8
Fr=51.13
Controlled fan frequency
9
Stabi=0.011
Standard deviation of the measurement value over 2
minutes
NOTE
Sabi: Typical result of a calibration is 0.015. Then calibration is finished.