UCD Console for UCD-340 User Manual | Unigraf Oy
64.
currently available). Variables defined are global except -
loops
variables which are
nested (they vanish when -
endloops
is reached). If there is a nested and global
variable of the same name, the nested variable is evaluated in expressions. Variables
created using an initializer list such as -
var
Name=N0,N1 will be named Name[0]
and Name[1] with values N0 and N1. Name itself is a variable and is the list SIZE
(two in this example). Values within braces can be variables and can be nested: -
var
Test=Skip[bool[1]],Skip[bool[0]].
•
-loops
starts a command loop with the target number of loops. The target can also
be a Name=Number or Name=VarName (a variable name) expression. The name
can be used in -c commands within the -loops block. Looping is to the next (same
nesting level)
-endloops
command option. Loops can be nested and there must be
the same number of
-loops
and
-endloops
command options.
•
-
continue
causes subsequent commands up to the
-loops
pairing
-endloops
to be
skipped.
•
-endloops
marks the end of a loop of the same nesting level started by the
previous
-
loops
command option.
•
-skip
is a no-operation and can be used with
-ontrue
.
•
-exit
exits scripting and prints a message (can be used with
-ontrue, -if -else -endif
).
•
-ontrue
is a conditional operator: If the preceding .read with expression (required)
was true, the next command (
-option
target) is run, else that following it is run. It
cannot be nested.
•
-timeout
will set the timeout time milliseconds (default is 10000) for commands that
require them.
•
-waiton
will wait for a
.read=Value.Expression
to become true or a time out (a
device must be open). Can be used to wait for a DUT to be plugged in, for example.
Its main purpose though is making sure CI’s to be tested are in a proper state for
reading as setting CI’s are asynchronous (see 1.2.4.1 EXAMPLES below).
•
-pic
is used to capture and save a picture to a file. A device sink must be open and a
DUT source must be connected for this to succeed. The format output is a lossless
bitmap (*.bmp).
•
-beginhtml
begins new html test report that receives output ONLY for tests (
-
c
.loadtd=
test.td). A device must be open. If the device is changed via a
-d Dev
command, the file will be closed (equivalent to
-endhtml
). The html output file will
be of the form <
devsink>_20181008105224_log.html
, where
<devsink>
is the
device name.
•
-endhtml
ends the current open html test report (a html file must be open).
•
-wpdosink
writes
device
sink
PDO
data
(see
TSI_USBC_PWR_LOCAL_SINK_PDO
) to a file.
•
-rpdosink
reads sink PDO data from a file and sets it on the open device.
•
-wpdosource
writes
device
source
PDO
data
(see
TSI_USBC_PWR_SOURCE_SINK_PDO
) to a file.
•
-rpdosource
reads source PDO data from a file and sets it on the open device.
•
-h
lists options and targets.
Examples
Looping colors spaces, patterns and timings (lastread below is a built-in global variable):
-timout 20000 #Wait on video signal
-d SourceDevice #defined in init.tsi
-c .read=TSI_R_PG_PREDEF_TIMING_COUNT;
-var SzT=lastread -pr "Timeing count is " -prvar SzT
-c .read=TSI_R_PG_PREDEF_PATTERN_COUNT;
-var SzP=lastread -pr "Pattern count is " -prvar SzP
-var dpix=10; #delta value for pixel width and height tests