![Unical NUA Скачать руководство пользователя страница 101](http://html1.mh-extra.com/html/unical/nua/nua_installation-and-maintenance-instructions-manual_3983475101.webp)
47
use and maintenance
INDICATIVE TABLE OF ROUTINE CLEANING OPERATIONS TO BE CARRIED OUT BY THE USER
Parts / Period
Maintenance
engineer
Every Day
Routine
2-3 Days
Routine
1 Month
Routine
2 Months
Routine
1 Year
Each Signal
Service
Extraordinary
Brazier
User
X
Ash pan compartment
User
X
X
Glass
User
X
X
Combustion chamber
walls and flue gas
diverter
User
X
Tee fitting
User
Technician
X
X
6.3 - EXTRAORDINARY CLEANING
CARRIED OUT BY A QUALIFIED
TECHNICIAN
Routine maintenance must be carried out at
least once a year and as often as the product
indicates 'SERVICE'.
The generator using pellets as solid fuel requires at least an-
nual routine maintenance which must be carried out by a
qual-
ified technician, using only original spare parts to restore
the combustion chamber seals.
Failure to do so may impair the safety of the appli-
ance and may invalidate the warranty conditions.
Observing the maintenance frequencies de-
scribed in the following user and maintenance
manual ensures that the heater will burn prop-
erly over time, avoiding any anomalies and/or
malfunctions that could require more technician
interventions.
Requests for extraordinary maintenance work are
not covered by the product warranty and are the
responsibility of the user.
HEAT EXCHANGER and ASH INSPECTION COMPART-
MENT
It is necessary to remove all combustion residues built up on
the walls of the heat exchanger and accumulated in the ash
inspection compartment up to the flue gas extractor.
GASKETS: FIRE DOOR , GLASS, ASH INSPECTION, ....
The gaskets ensure that the stove is airtight and that it func-
tions properly.
They must be periodically checked: if they are found to be worn
or damaged, they must be replaced immediately, otherwise the
product will not function properly.
These operations must be carried out by a qualified technician.
AIR PRESSURE SWITCH CONNECTION
It is necessary to remove soot from inside or close to the air
intake connection of the pressure switch connected to the com-
bustion chamber. This is done by unhooking the silicone tube
and blowing into the fitting or using a special tool.
ROOM FAN
During operation of the product, an accumulated layer of dust
is generated on the room fan due to the recirculation of air in
the room. It is necessary to remove the dust with a soft brush,
avoiding knocks against the fan, otherwise it will be damaged.
CHIMNEY and SMOKE DUCT
Chimney connection
Annually or whenever the need arises, vacuum and clean the
duct leading to the chimney. If there are horizontal sections, it
is necessary to remove residue before it obstructs the passage
of flue gas.