4) INCREASE LID TENSION (BY ADJUSTING THE SPRING BOLT)

CAUTION:

SHOULD BE DONE ONLY AS A LAST RESORT - FIRST CHECK FOR A WORN LID GASKET, A BLOCK-
AGE IN THE SOLVENT FLOW PATH , LOOSE HINGE BOLTS OR A SET POINT THAT IS TOO HIGH 
FOR THE SOLVENT BEING RECYCLED.

5) REPOSITION LID and TIGHTEN HINGE BOLTS
The Hinge bolts can loosen over time, causing the lid to shift off  center. This can lead to an inadequate 
seal and leaking around the Gasket. Loosen the bolts, reposition the lid and re-tighten the bolts.  

This procedure tightens the Lid by increasing 
the tension on the spring attached to the Lid 
Bar Spring Bolt Assembly. The Lid and Bolt 
Assembly is carefully designed as a Safety 
Pressure Relief system to prevent a danger-
ous build up of pressure inside the closed 
tank.

 Do not adjust the Spring Holding Nut 

by more than 2 full turns maximum.

 If 2 

full turns do not solve the problem, call for 
service.

•  While holding the top nut with a wrench, 

turn the Spring Holding Nut no more than 
a 1/2  turn at a time. Turn in a counter- 
clockwise direction (as you look down on 
it).

•  After each 1/2 turn, operate the unit nor-

mally and check for leaks.

Spring Holding Nut

Top Nut

Hinge

Spring Bolt Assembly

Spring Bolt Assembly

Cross Bar

6) RECOMMENDED 6-MONTH MAINTENANCE
• 

Vacuum the condenser (see Service Procedure 1).

• 

Clean the solvent fl ow path by recycling 3 Gal of clean solvent.

• 

Inspect Distillation Tank for debris, pitting and/or other damage.

• 

Inspect Lid Gasket for wear or damage (see Operating Procedure 11).

Содержание URS1600 Series

Страница 1: ...USER MANUAL URS1600 SERIES URS2000 SERIES RI 80 UNI RAM CORPORATION ONTARIO CANADA Revised 2019 05 URS2000 URS1600...

Страница 2: ...temperature must be between 5 C 41 F to 35 C 95 F DO NOT RECYCLE NITROCELLULOSE WHICH IS EXTREMELY VOLATILE IT AUTOMATICALLY IGNITES AT 135 C TO 166 C 275 F TO 330 F Do not install operate or maintai...

Страница 3: ...2 No 30 and No 88 by ETL Approved for use in non hazardous locations as well as approved for use in hazardous locations Class 1 Division 1 Group D and Class 1 Division 2 Group D Explosion proof const...

Страница 4: ...one 1 locations where solvents may be present See Hazardous Location in the National Electrical Code for more information If this unit is placed in a Class 1 Division 2 Zone 2 or unclassi ed location...

Страница 5: ...r thin ner paint thinner acetone and other paint diluents Flammable Solvents have a ash point below 38 7 C 100 F These solvents are commonly used in the industry as a cleaning solvent or as a paint di...

Страница 6: ...ank Fill to 3 below retainer ring 4 Check distillation conditions and change if necessary using SETUP MODE 5 Recycling 6 Finish Recycling 7 Transfer clean solvent 8 Remove waste debris 9 Clean Distill...

Страница 7: ...Out Hose to the Solvent Out port of the unit and insert the other end with the Outlet Tube into the drum container The Outlet Tube must extend below the rim of the pail to prevent solvent spillage If...

Страница 8: ...the following conditions decrease POWER by one increment or more vapour leaks at the Lid Gasket recycled solvent comes out too hot waste material is carried into the recycled sol vent Otherwise use 1...

Страница 9: ...anel shows the Software Version then READY S P XXX C S P SET POINT When Setup is complete and START has been pressed the HEAT light comes on and the recyling process begins During the boiling phase 3...

Страница 10: ...t stainless steel one Lid Surface Use a cloth Dry and clean the lid and the top of tank where the the Lid Gasket sits to extend the life of the Lid Gasket and prevent leakage Avoid rotating the lid du...

Страница 11: ...a cooling condenser where puri ed clean solvent ready for use condenses out Waste materials in the dirty solvent boil at a temperature substantially above the Tem perature Set Point so they remain in...

Страница 12: ...r heat transfer due to dirt and debris left in the tank 1 Clean the tank replace the Liner Bag recycle with pure solvent to test If suc cessfull the problem is due to a dirty tank debris left in the t...

Страница 13: ...ars to be operating erratically The computer may require re booting Disconnect the power supply for 30 sec onds Restore power and operate unit Residue puck in Tank is too wet 1 BAKE TIME is not long e...

Страница 14: ...R HEAT Over heating occurred at the Condenser The Condenser is dirty or the Fan stopped for another reason see below Clean the Con denser When the Fan Motor has recovered 4 5 min this mes sage will di...

Страница 15: ...t Tube If the blockage persists blow air at about 30 PSI 2 kg cm2 into the Vapour Outlet If the air comes out of the Solvent Outlet Tube the blockage has been cleared If not call for service 3 REPLACE...

Страница 16: ...ssembly The Lid and Bolt Assembly is carefully designed as a Safety Pressure Relief system to prevent a danger ous build up of pressure inside the closed tank Do not adjust the Spring Holding Nut by m...

Страница 17: ...BAG MAY VOID THE WARRANTY DESCRIPTION PART NO SAFETY COVER 960 3310H KEYPAD 900 3461 DIAPHRAGM PUMP UDP4TA RECEIVING CONTAINER 960 9010 LID GASKET NEOPRENE URS1600 790 2150NF LID GASKET NEOPRENE URS2...

Страница 18: ...y or claim either expressed or implied with respect to this product s tness for any purpose or the result to be obtained from its use This condition applies to the sale of all products and no represen...

Отзывы: