background image

15

MANUAL - SOLVENT RECYCLERS  -  URS1600 SERIES, URS2000 SERIES & RI 80 Rev 2019-05

SERVICE PROCEDURES

 

1) CLEAN CONDENSER
Remove the 2 screws at the back of the Side Cover and carefully move the Side Cover forward just 
enough to reach the front of the condenser with a vacuum. Using a brush attachment, vacuum the front of 
the condenser where most of the dust accumulates and then vacuum the back if necessary. Put the Side 
Cover back into position and re-install the screws.

2) CLEAR BLOCKED SOLVENT FLOW PATH

CAUTION: 

WEAR SAFETY GOGGLES.

A blockage in the solvent fl ow path (Vapour Outlet - Condenser - Solvent Outlet Tube) can cause solvent 
to leak. To determine the location of the blockage, fi rst check the Solvent Outlet Tube and the Vapour 
Outlet Fitting for visible signs of blockage or damage. If the problem is not in either of these locations, the 
Condenser is problably blocked. To clear the condenser, pour some clean solvent into the Vapour Outlet 
and check if it comes out of the Solvent Outlet Tube. If the blockage persists, blow air at about 30 PSI (2 
kg/cm2) into the Vapour Outlet. If the air comes out of the Solvent Outlet Tube, the blockage has been 
cleared. If not, call for service.
3) REPLACE FUSES
Fuses are located on the Power Control Board inside the Motor Housing.
•  Disconnect power supply.
•  Remove the Guard Screen by unscrewing two metal screws to get access to the Motor Housing

•  Unscrew the 6 screws from the Front Cover and pull it gently from the motor housing to expose the 

fuses. 

Note: Care should be taken not to pull the Front Cover too far as some wires may discon-

nect.

Fuses F1 & F2: 240 VAC, 20A (URS2000) or 30A (URS2000PW & RI 80), 3AG, fast action, for Heater
Fuses F3 & F4: 25 VDC, 2.0 A, 3AG, slow action, for Fan Motor   
Fuse F5: 240 VAC, 0.0625 A, 3AG, fast action, for Computer Board

•  Remove the fuses from the board and, using a meter, test each one and replace as needed.
•  Carefully push the Power Control Board back into the Motor Housing. 
•  Ensure that the wire to the computer board is secure.
•  Re-install the Front Cover using all 6 screws..
•  Install the Guard Screen using two metal screws.
•  Close the Door and re-connect the power supply.

Motor Housing

Power Control Board

Front Cover

Содержание URS1600 Series

Страница 1: ...USER MANUAL URS1600 SERIES URS2000 SERIES RI 80 UNI RAM CORPORATION ONTARIO CANADA Revised 2019 05 URS2000 URS1600...

Страница 2: ...temperature must be between 5 C 41 F to 35 C 95 F DO NOT RECYCLE NITROCELLULOSE WHICH IS EXTREMELY VOLATILE IT AUTOMATICALLY IGNITES AT 135 C TO 166 C 275 F TO 330 F Do not install operate or maintai...

Страница 3: ...2 No 30 and No 88 by ETL Approved for use in non hazardous locations as well as approved for use in hazardous locations Class 1 Division 1 Group D and Class 1 Division 2 Group D Explosion proof const...

Страница 4: ...one 1 locations where solvents may be present See Hazardous Location in the National Electrical Code for more information If this unit is placed in a Class 1 Division 2 Zone 2 or unclassi ed location...

Страница 5: ...r thin ner paint thinner acetone and other paint diluents Flammable Solvents have a ash point below 38 7 C 100 F These solvents are commonly used in the industry as a cleaning solvent or as a paint di...

Страница 6: ...ank Fill to 3 below retainer ring 4 Check distillation conditions and change if necessary using SETUP MODE 5 Recycling 6 Finish Recycling 7 Transfer clean solvent 8 Remove waste debris 9 Clean Distill...

Страница 7: ...Out Hose to the Solvent Out port of the unit and insert the other end with the Outlet Tube into the drum container The Outlet Tube must extend below the rim of the pail to prevent solvent spillage If...

Страница 8: ...the following conditions decrease POWER by one increment or more vapour leaks at the Lid Gasket recycled solvent comes out too hot waste material is carried into the recycled sol vent Otherwise use 1...

Страница 9: ...anel shows the Software Version then READY S P XXX C S P SET POINT When Setup is complete and START has been pressed the HEAT light comes on and the recyling process begins During the boiling phase 3...

Страница 10: ...t stainless steel one Lid Surface Use a cloth Dry and clean the lid and the top of tank where the the Lid Gasket sits to extend the life of the Lid Gasket and prevent leakage Avoid rotating the lid du...

Страница 11: ...a cooling condenser where puri ed clean solvent ready for use condenses out Waste materials in the dirty solvent boil at a temperature substantially above the Tem perature Set Point so they remain in...

Страница 12: ...r heat transfer due to dirt and debris left in the tank 1 Clean the tank replace the Liner Bag recycle with pure solvent to test If suc cessfull the problem is due to a dirty tank debris left in the t...

Страница 13: ...ars to be operating erratically The computer may require re booting Disconnect the power supply for 30 sec onds Restore power and operate unit Residue puck in Tank is too wet 1 BAKE TIME is not long e...

Страница 14: ...R HEAT Over heating occurred at the Condenser The Condenser is dirty or the Fan stopped for another reason see below Clean the Con denser When the Fan Motor has recovered 4 5 min this mes sage will di...

Страница 15: ...t Tube If the blockage persists blow air at about 30 PSI 2 kg cm2 into the Vapour Outlet If the air comes out of the Solvent Outlet Tube the blockage has been cleared If not call for service 3 REPLACE...

Страница 16: ...ssembly The Lid and Bolt Assembly is carefully designed as a Safety Pressure Relief system to prevent a danger ous build up of pressure inside the closed tank Do not adjust the Spring Holding Nut by m...

Страница 17: ...BAG MAY VOID THE WARRANTY DESCRIPTION PART NO SAFETY COVER 960 3310H KEYPAD 900 3461 DIAPHRAGM PUMP UDP4TA RECEIVING CONTAINER 960 9010 LID GASKET NEOPRENE URS1600 790 2150NF LID GASKET NEOPRENE URS2...

Страница 18: ...y or claim either expressed or implied with respect to this product s tness for any purpose or the result to be obtained from its use This condition applies to the sale of all products and no represen...