Table 6-2
Perimeter Parameter Description
Parameter
Description
Setting
Channel
Channel 1: visible.
Channel 2: thermal.
Choose one channel to set.
Enable
Enable the button to enable the alarm.
[How to set]
Click Enable to enable.
[Default value]
OFF
Limit Target
Type
Effective alarms are set based on target
type, with options of Person or Car,
person, car. When the device is used
indoors, because of small space and
large targets, to avoid wrong alarms are
triggered b person even if car is
selected, it is recommended to set the
target type to person for indoor use.
[How to set]
Click to enable Limit Target
Type.
[Default value]
OFF
Limit Target Size The target size for triggering an
effective alarm is set based on the actual
target size. The minimum size is 1000
square centimeters and the maximum
100000 square centimeters. When
setting the target size, you need to well
set “Real size in scene” in advanced
parameters; otherwise no alarms may be
generated.
[How to set]
Click to enable Limit Target
Size.
[Default configuration]
OFF
Upload Target
Info
Enable the function of uploading target
information by clicking
below
the real-time video in a browser to turn
into
. When an alarm is
triggered, the target movement trace can
be displayed (The trace can be seen only
within the deployment area and
disappears after the target leaves the
deployment area).
[How to set]
Click to enable Upload
Target Info.
[Default value]
OFF
Out Channel
If you check to set the Output Channel
and the device is connected to an
external alarm indicator, the alarm
indicator signals when an alarm is
triggered.
[How to set]
Click to select an ID.