Parameter
Description
Setting
Correction
Coefficient
Correction coefficient refers to
the deviation of measured
object temperature and actual
temperature.
For example:
1. The measured object
temperature is 30, and actual
temperature is 37, so the
correction coefficient is
7.
2. The measured object
temperature is 37, and actual
temperature is 30, so the
correction coefficient is -
7.
[Setting method]
Enter a value manually.
[Default value]
0.00
Mount distance
The actual distance between the
detection person and the device,
it is set to facilitate the
temperature measurement
accuracy.
[Setting method]
Enter a value manually.
[Default value]
5.00
Face color
Enable, if the carmera detect the
face and the face will be
covered color, normal is
yellow, and high temperature is
red, as shown in figure.
[Default value]
Disable
Environment
adaptation
Enable, the device will restart
the temperature if the ambient
temperature of camera varies
greatly. It is recommended not
to open.
[Default value]
Disable
Abnormal
temperature
display
Enable, the measure
temperature is lower than 34 ℃
will show on OSD.
Disable, the measure
temperature is lower than 34 ℃
will not show on OSD.0
[Default value]
Disable
Temperature area
Two modes, shows at themal
channel. Mode 1 is full face
area, mode 2 is forehead area.
[Setting method]
Select a value from the
drop-down list box.
[Default value]
Mode 1