Bi-spectrum network camera
User Manual
Thermal Sensor Configuration
Issue V 1.0
(
2020-10-19
)
59
Parameter
Description
Setting
temperatures collected by the internal
temperature probe. The temperature of the
camera sharply changes when the camera is
powered on. The FFC is relatively frequent,
which is normal.
Manual
: In the manual FFC mode, the camera
does not automatically perform the FFC based on
the temperature change or the specified period.
You can press the Do FFC button to select the
manual FFC mode. When you feel that the image
is obviously degraded but the automatic FFC is
not performed, you can use the manual FFC
function to check whether the image quality can
be improved.
FFC
interval
(min)
In the automatic FFC mode, the FFC interval
ranges from 10 to 255 minutes. When the time
reach to setting value, the camera do shutter
adjust operation automatically.
[How to set]
Select by
dragging the
slider.
[Default value]
15
Tempr
interval
In the automatic FFC mode, the tempr interval
value ranges from 5 to 255 degree centigrade.
When the time reach to setting value, the camera
do background adjust operation automatically.
[How to set]
Select by
dragging the
slider.
[Default value]
5
Shutter
initialization
Click the icon and shutter will be initialized
Manually
Shutter
adjust
Click the icon and camera perform the action.
Manually
Background
adjust
Click the icon and camera perform the action.
Manually
----End
5.7 Noise Reduction
Figure 5-7 shows the
Noise reduction
interface.