YK15-0009-DI-002-04
47
6. Removal / transport
6.1 Operation procedure
(1) Stop the Pump, and set the inside of the Pump to the atmospheric pressure.
(2) Shut the electricity supply and remove the cable connection.
(3) Discharge the lubrication oil.
(4) Remove the Suction/exhaust piping and put Blind flanges to the Pump inlet and outlet to seal
them up
DANGER
①
Use of the toxic, combustible or combustion susceptible gas and
substance other than inactive gas is not allowed by the vacuum pump.
Pump oil as well as the Pump unit becomes toxic should the toxic gas
was sucked in the vacuum pump. Pay attention to execute
maintenance work.
②
You should replace with the nitrogen gas completely the Pump that
exhausted any special gas. Note further that only the entitled person
for special gas handling should be in charge of the removal work.
③
Keep applying a plate displaying the name of exhausted gas on a
place easily seen on the Pump.
WARNING
①
You have a risk of giving damage to your back as the load larger than
safety standard shall be required to transfer this product.
VD30C: 58kg
VD40C: 60kg
VD60C: 90kg
VD90C: 113kg
Be sure to use the loading machinery (such as mobile crane) to lift up
the Pump or load it on the pallet and fix it and run the Pallet truck for
its transfer.
②
Never try to enter beneath the Pump unit when lifted it up.
Use its top eyebolt to load/unload the unit.
Содержание VD30C
Страница 2: ......
Страница 3: ......
Страница 4: ......
Страница 31: ...YK15 0009 DI 002 04 10 Fig 6 Dimensional drawing VD60C Fig 7 Dimensional drawing VD90C...
Страница 32: ...YK15 0009 DI 002 04 11 Fig 8 Dimensional drawing VD30C H VD30C B Fig 9 Dimensional drawing VD40C H VD40C B...
Страница 33: ...YK15 0009 DI 002 04 12 Fig 10 Dimensional drawing VD60C H Fig 11 Dimensional drawing VD90C H...
Страница 78: ......