background image

 

 

 

 

  ・

Cautions for Safety in Use 

 

 
 

Applications 

(1)  This pump is not designed to be explosion-proof, and should therefore not be used to 

discharge explosive gases. 

(2)  In addition to discharge of gas via the outlet, gas may also leak from other parts of the pump, 

and it should therefore not be used with toxic gases. If toxic gas is discharged for any reason 
it is important to note that the interior of the pump will be contaminated by the gas, requiring 
appropriate caution during maintenance.

 

Maintenance and Repair   

(3) 

When requesting the manufacturer’s service division to dismantle and repair the pump, always 
note the gas which the pump has been used with on the Usage Check Sheet. Note that if it 
has been used to discharge toxic gas for any reason it will be contaminated. Please be aware 
that use with some gases will preclude dismantling and repair. 

Leakage rate 

(4)  The amount of the leakage of this pump is recorded. Use it in consideration of the leak rate. 

The helium gas is used for the Leak examination. Leakage rate:2.6×10

-4

 

  Pa

m

3

/sec 

The measurement of the amount of Leake rate the inside of the pump a vacuum and is a   

measurement of the amount of penetration of the helium gas

(5)  The  amount  inspection  of  leaks

Flux  inspection  by  the  side  of  an  exhaust  gas  by  attainment 

pressure

0.03L/min 

Suck gas   

(6)The pump is not designed to prevent leakage of harmful/poisenous/toxic gas. 
(7) In case it is used with toxic/corrosive gases proper safety measures shall be implemented by 

the end user of which adequacy needs to be evaluated upon installation.   

These measures may include employment of safety ducting system, leakage detection   

system etc. depending on a comprehensive risk assessment

 

(8) The vacuum vessel that enters the gas that influences the harmful gas or the human body like 

the noxious fume and the environment is exhausted in the vacuum with this pump. There is 
causing the poisoning accident and the fatal accident at that time when the vehicle exhaust 
emission of the pump is indoors opened.

 

Please do the following countermeasure and use 

the pump safely. 

Suck gas [corrosive gases]

 

(9)  It is necessary to connect the vehicle exhaust emission of the pump with a special ventilation 

duct or exclusion device. And, do not discharge the vehicle exhaust emission indoors.     

(10)  Please confirm the thing that doesn't leak to the piping of the pump inhalation side and the 

exhalation side. 

(11)  It is necessary to install the gas leakage detector for the suck gas on the device. When the 

leakage is detected, it is necessary to do the setting that intercepts the gas inflow to the pump. 

(12)  Please exchange the consumable parts to prevent the leakage from the pump every 5000 

hours. ( The bearing is excluded.) 

(13)  Please take shelter at once when the gas leaks by any chance due to the breakdown of the 

pump. And, please ventilate the air in the room enough. Moreover, please enter the room of 
the device after wearing the hazard mask when you confirm the device. Do not detach the 
hazard mask until safety is confirmed. 

Suck gas [flammable gases]

 

(14)  The mixed gas within the range of the explosion prohibits exhausting. 
(15)  It is necessary to connect the vehicle exhaust emission of the pump with a special ventilation 

duct or combustion device. And, do not discharge the vehicle exhaust emission indoors. 

(16)  Please confirm the thing that doesn't leak to the piping of the pump inhalation side and the 

exhalation side. 

It is necessary to install the gas leakage detector for the suck gas on the device. When the   
leakage is detected, it is necessary to do the setting that intercepts the gas inflow to the   
pump.Please exchange the consumable parts to prevent the leakage from the pump every   
5000 hours. (The bearing is excluded.)

 

 

!

Danger 

04 

Содержание DTU-20 Series

Страница 1: ...sers Please read this manual thoroughly to ensure safe and effective use of the equipment Keep this manual in a safe place Due to periodic improvements in performance the equipment described in this m...

Страница 2: ...nd vacuum pumps Safety requirements Part2 Vacuum pumps IEC EN 61010 1 2010 A1 2019 Safety requirement for electrical equipment for measurement control and laboratory use Part1 General requirement foll...

Страница 3: ...nformity with the following standards BS EN 1012 2 1996 A1 2009 Compressors and vacuum pumps Safety requirements Part2 Vacuum pumps BS IEC EN 61010 1 2010 A1 2019 Safety requirement for electrical equ...

Страница 4: ...n 4 3 3 Installation location 4 3 4 Electric wiring 5 3 5 Fluctuations in the power voltage and frequency 5 3 6 Piping 6 3 7 Storage 6 4 Caution in Operation 7 4 1 Caution in Operation 7 4 2 When Ther...

Страница 5: ...t information service bases and contact information Drawing List Fig 2 1 DTU 20 Appearance 3 Fig 3 1 Change region of the voltage and frequency 5 Fig 3 2 Piping Example for Evacuation of Container 6 T...

Страница 6: ...pment correctly Read the section on Safe Use particularly closely Keep This Manual in a Safe Place After reading this manual be sure to keep it in a safe place which is readily accessible to others ne...

Страница 7: ...ed to inlet and outlet x 2 3 Is the pump damaged in any way 4 Are any external screws or inlet and outlet pipes loose Are any components missing Contact your agent or the sales division of the manufac...

Страница 8: ...r Incorrect handling of the equipment may result in death or serious injury to the operator Incorrect handling of the equipment may result in light or medium injuries to the operator or damage to the...

Страница 9: ...or the human body like the noxious fume and the environment is exhausted in the vacuum with this pump There is causing the poisoning accident and the fatal accident at that time when the vehicle exha...

Страница 10: ...s equipped with a cord having a grounding wire with an appropriate grounding plug the plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and...

Страница 11: ...this may result in the motor burning out or fire 10 Do not damage modify pull the power cord or place objects on it Damage to the cord may result in electric shock or fire 11 Always fully insert the...

Страница 12: ...g components eg motor main shaft axial joints cooling fan while the pump is in operation may result in injury 6 The overload protector operates when the pump becomes excessively hot Touching it in thi...

Страница 13: ...r compressed and gases into the pump will result in damage and prevent proper operation 7 Ingestion of rubbish and dust in the air entering the pump will interfere with its proper function If the air...

Страница 14: ...pump It is recommended to wipe off chemicals attached regardless description in the followings Acetone Ethyl ether Ethyl acetate Flora and fauna oil etc 5 Never absorb the gas that mixed dust dust mo...

Страница 15: ...owever the condensable gas remains in the pump chamber if large quantity of condensable gas is exhausted or after having exhausted condensable gas without opening a gas ballast valve because of a limi...

Страница 16: ...2 Appearance Fig2 1 DTU 20 Appearance...

Страница 17: ...No danger of fire i When Equipment is installed temperature in pump circumference shall not exceed 40 104 degF 3 3 Installation location Select a location where dust and moisture are small and install...

Страница 18: ...the voltage change and frequency change in Domain A in main rated values it operates continuously and can be used practically convenient and to the voltage change and frequency change in Domain B it...

Страница 19: ...f selecting the inlet pipe and exhaust pipe that are not from our products please select the exhaust pipe that has same or larger inner diameter length with the inlet pipe 6 When connecting a pipe to...

Страница 20: ...perated at first turn off the pump power supply push to side and disconnect power cable Contact Ulvac or local agent Temperature of the pump is very high at this time Do not touch the pump by hand def...

Страница 21: ...follow the procedure described below 1 Open the inlet port to atmosphere and repeat switch ON OFF two or three times until the pump starts If still it does not start warm up the ambient temperature t...

Страница 22: ...and piping make the ultimate pressure higher 2 Ultimate pressure becomes higher in case there is resource of gas such as vacuum leakage in the vacuum route 5 2 Exhaust velocity Flow rate of the diaph...

Страница 23: ...ion 1 Replacement of diaphragms 2 Replacement of valves 6 2 Maintenance During an operation of the vacuum pump check the following items at least once in 3 days 1 Generation of abnormal noise 2 Abnorm...

Страница 24: ...s List Part name Quantity Material Reference life Diaphragm 4 Main body Synthetic rubber EPDM Parts exposing to gas PTFE 6 000 hr Valve 6 FFKM 6 000 hr Valve With hole 2 Bearing 1 set 15 000 hr Kalrez...

Страница 25: ...air and there is a risk to go into the human body when breathing Confirm that pump power source is disconnected from outlet or terminal blocks before conducting replacement work without fail Confirm...

Страница 26: ...pper and lower 1 Panel Both sides 6 Opposite side 13 mm 0 5 spanner insertion openings 4 positions 7 Casing cover 5 Handle 1 Replacement of diaphragm valves It is recommended to replace all sheets at...

Страница 27: ...ntation as shown in right drawing Upper level pump head mounting direction Notch direction Mount the lower level valve in orientation as shown in left drawing Lower level pump head mounting direction...

Страница 28: ...phragm and tighten with a spanner of opposite side 13 mm 0 5 lightly Afterwards tighten with a torque spanner in 4N m as final tightening 11 Align a direction of the pump head and attach it on the dia...

Страница 29: ...right and switch plug terminal and ground simultaneously 19 Attach Handle 20 In the last confirm whether screws or valves besides the parts replaced are not left If anything left it would be conceiva...

Страница 30: ...de inspection of pump head 15 Abnormal bearing 15 Replacement 6 4 16 Miscellaneous Damage of pump internal parts 16 Overhaul replacement of damaged parts 6 4 Pressure failed to drop 1 Pump is small fo...

Страница 31: ...in the status that absorption gas pressure is high 1 Do not conduct continuous operation in vicinity of atmospheric pressure 2 Absorption gas is high temperature 2 Mount refrigerating machine such as...

Страница 32: ...and inspection etc d Malfunctions caused by modifications or repairs carried out by a party other than the manufacturer or by a service company not approved by the manufacturer e Malfunctions caused...

Страница 33: ...US 13 L form nipple 1 PP 43 Setscrew 4 SUS 14 Valve retainer 1 1 Fluoroplastics 44 Pan machine screw 6 SUS 15 Valve retainer 2 1 Fluoroplastics 45 Setscrew 4 SUS 16 Gas ballast nipple 1 PP 46 Pan mach...

Страница 34: ...Exploded view...

Страница 35: ...Industrial Safety and Health Law designates particular substances as the materials to be notified 2 Usage Status Operation Method Approx hours per day years and months Continuous Operation Intermitte...

Страница 36: ...C KIKO Inc https ulvac kiko com en Please contact us for products Service Base or other Inquiries from here ULVAC Inc Components Business HQ 2500 Hagisono Chigasaki Kanagawa 253 8543 Japan TEL 81 467...

Отзывы: