DC Pulse Power Supply
【
DC-5-P/DC-10-P
】
5
HOW TO OPERATE
62
Table 5-6: USER control signal connecting equivalent circuit
Signal type
Signal
Pin
Equivalent circuit
DI
Digital input
DC OFF
※
1
8
+15V
PLC etc
4.3kΩ
DI
DC-5-P/10-P
AD INTERFACE side
DC ON
10
PULSE
PARAM SEL
15
RESET
26
PREG
27
IREG
28
DC MODE
30
ONE PULSE
MODE
31
INTERLOCK
37
DO
Digital output
READY
11
COMD
PLC etc
100Ω
DO
1000p
DC-5-P/10-P
AD INTERFACE side
COMD
OUTPUT
12
SETPOINT
13
FAIL
14
HARC
16
REMOTE
35
AI
Analog input
LEVEL
※
2
21
LEVEL
COM L
2.2kΩ
COM A
PLC etc
DC-5-P/10-P
AD INTERFACE side
COM L
+
-
ISO AMP
COM L
AO
Analog
output
VOUT
2
AO
ISO AMP
COM A
COM A
COM A
DC-5-P/10-P
AD INTERFACE side
PLC etc
-
+
100
COM A
IOUT
3
POUT
4
*1: Only a DC OFF signal is Active High. The output is stopped at High Level.
*2 Use the LEVEL signals as: 10.0Vmax for P control; 10.0Vmax for I control; 5.34Vmax for V control (5kHz to
150 kHz); and 4.34Vmax for V control (155kHz to 250 kHz).
When surpassing the above level, the output is restricted in the rated power, and if the level is further
increased, the output is stopped by ERROR.