DC Pulse Power Supply
【
DC-5-P/DC-10-P
】
4
DESCRIPTION OF FUNCTIONS
41
4-12. Display of error code and warning code on front panel
When an error and a warning occur, an occurrence code is described in the front panel of the power
supply.
Displayed error codes, warning codes, and the content is as follows.
Table 4-15: Error code list
Error name
Code
Error content
MODULE ERROR
E10*
This occurs if the M/S address settings are wrong.
CAN TIMEOUT ERROR
E21*
It occurs in the event of a communication error between
M/S.
FUSE ERROR
E30*
This occurs if the internal FUSE is blown.
DC OVER CURRENT ERROR
E31*
Generates when an overcurrent is occurred in the DC
output
BUS OC ERROR
E32*
This occurs at an overcurrent of the BUS current.
PRC ERROR
E33*
Generates when the detection of reverse-electric-current
value is abnormal.
TEMP ERROR
E34*
This occurs if an internal temperature error occurs.
FAN ERROR
E35*
This occurs in the event of a cooling FAN error.
INVERTER ERROR
E36*
Generates when the inverter is abnormal
CPU ERROR
E37*
Occurs in the event of a control circuit board error.
E38*
E39*
E3C*
E3F*
EMERGENCY STOP RUN ERROR
E3A*
This occurs when emergency stop works.
POWER DEPRESSION ERROR
E3B*
This occurs when the output drops.
PULS OVER CURRENT ERROR
E3D*
Generates when an overcurrent is occurred in the pulse
output
PULS CIRCUIT ERROR
E3E*
Generates when the pulse section is abnormal
SYNC SETTING ERROR
E40*
Generates when the pulse synchronization is incorrectly
specified.
IN FREQ ERROR
E41*
Generates when the external clock signal is out of the
operational range.
LEVEL OVER ERROR
E60*
This occurs when a command voltage and an overcurrent.
PCB SETTING ERROR
E70*
This occurs when M/S consists of DC-5-P and DC-10-P
specifications.
* is the power supply number corresponding to M/S. (See Table 4-16.)
Ramp time
Содержание DC-5-P
Страница 81: ...DC Puse Power Supply DC 5 P DC 10 P 8 APPENDIX 69 Figure 8 2 External view of DC 10 P...