DC Pulse Power Supply
【
DC-5-P/DC-10-P
】
2
OVERVIEW
5
2-4. Specifications
2-4-1. Electrical specification
Table 2-1: Electrical specification
Item
Specifications
Type
DC-5-P
DC-10P
In
p
u
t s
p
ec
ifi
ca
tio
n
Rated input voltage
AC208V
AC208V
Input voltage
variation range
AC187V
~
229V
Number of phases /
Frequency
3 phase: 50/60 Hz
Input connection
Connector
Connector
Input current
30A or less
※
1
50A or more
※
1
Input capacity
8kVA or less
※
1
13.5kVA or less
※
1
Leakage current
5.5mA or less
5mA or less
Efficiency
87
%
or more
※
1
87
%
or more
※
1
Power factor
0.81 or more
※
1
0.85 or more
※
1
O
u
tp
u
t
sp
ec
ifi
ca
tio
n
Rated power
5kW
10kW
Rated current
12.5A
25A
Rated voltage
5kHz
~
150kHz
:
800V 155kHz
~
250kHz
:
650V
※
2
Ignition voltage
1500V
Oscillating frequency
5kHz
~
250kHz
From 5 to 150kHz: Selectable in the unit of 1kHz
From 150 to 250 kHz : Selectable in the unit of 5kHz
Inversion pulse width
0
.4μs
~
5μs
: Selectable in the unit of
0.1μs
※
2
Output range
Oscillating frequency
5kHz
~
150kHz
Oscillating frequency
155kHz
~
250kHz
Oscillating frequency
5kHz
~
150kHz
Oscillating frequency
155kHz
~
250kHz
V2
800V
1.5A
12.5A
V4
200V
6.25A
V3
400V
5kW
I3
I2
I1
V1
1500V
V2
650V
1.5A
12.5A
V4
200V
7.69A
V3
400V
5kW
I3
I2
I1
V1
1500V
V2
800V
2.5A
25A
V4
200V
12.5A
V3
400V
10kW
I3
I2
I1
V1
1500V
V2
650V
2.5A
25A
V4
200V
15.38A
V3
400V
10kW
I3
I2
I1
V1
1500V
V1
1500V
1500V
V1
1500V
1500V
V2
800V
650V
V2
800V
650V
V3
400V
400V
V3
400V
400V
V4
200V
200V
V4
200V
200V
I1
1.5A
1.5A
I1
2.5A
2.5A
I2
6.3A
7.7A
I2
12.5A
15.4A
I3
12.5A
12.5A
I3
25A
25A
Output polarity
Negative polarity
ARC control
Inter-pulse ARC function: Continuous mode
HARD ARC function: Continuous mode, One-pulse mode, and DC mode*
During the HARD ARC operation, the operation of the inverter is stopped in addition to the stop of the
reverse-pulse output.
*During the DC mode, the reverse-pulse output is not carried out. Only the inverter is stopped.
Output connection
Connector
C
o
n
tr
o
l
Operation mode
system
LOCAL mode/USER mode/HOST mode (SERIAL communication control (RS-232C or RS-485))
/HOST+
mode(USER + HOST mode)
Output control
system
Constant power control (P control) / Constant current control (I control) / Constant voltage control (V
control)
Control accuracy
The higher of ±0.5% or less of the rated output or ±1% of the set value
Guaranteed control
range
Constant power control: 10 to 100% of the rated power value
*1 Subject to change according to the customer's use condition and the input facility.
*2 Limited by present oscillated frequency. For details, refer to Fig.2-1.