GD-36
28
23
610.396A
rev.
1
7.1.6.- PROGRAM LIST
The user can select any program (from program 00 to program 99) that has been previously configured, using the "
UP
" and
"
DOWN
" buttons in the "
PROGRAM LIST
" area. The list shows the selected programme number and the total number of
programmes stored in memory. Once the desired programme has been selected, it will be activated after pressing the "
PLAY
PROGRAM
" button. Programmes that have the special "
DIRECTPLAY
" mode (which does not have an associated time event)
can only be run manually from this list. During the time the programme is active, the status display will show the "
SCHEDULE
"
mode and the name of the programme being broadcast. It is possible to stop the message playback by pressing the "
STOP
"
button in the
"PLAYER CONTROL" 7.1.2.
7.1.
By simulated LED indicators, it indicates the status of the 10 output remote controls and the general remote control of the GD-36
"
TLM
". The illuminated LED indicates active remote control, the LED off indicates remote control in standby.
7.1.8.- INPUTS
By means of simulated LED indicators, it indicates the status of the 10 input remote controls and the GD-36 "
INH
" inhibition
remote control. The illuminated LED indicates active remote control, the LED off indicates remote control at rest.
7.1.
OTHERS
It simulates the LED indicators located on the front of the GD-36:
FAULT, MESSAGE, MUSIC
and
REC
, having the same
functionality.
7.1.10.- POWER (On / Off)
The GD-36 can be switched off (standby) and on by
remote control using the "
POWER
" button.
When the equipment is in standby mode, or low
consumption, the remote display will appear:
7.- OUTPUTS
9.-
7.2. SYSTEM NETWORK
This page allows the configuration of the network interface of the GD-36.
Don't forget to press the "
SAVE NETWORK
" button to save the changes you have made. The changes will take effect the next
time the GD-36 is started.
When manual mode is selected, you must specify the rest of the parameters and press the "
SAVE NETWORK
" button to save; if
you do not have enough information, it is recommended to contact your local network administrator to provide them (See section
6.4.1 Ethernet Configuration).
CAUTION:
Incorrect configuration may cause the GD-36 to lose network connectivity. If you are in doubt about the settings, do
not hesitate to contact your network administrator.