background image

7

© 2021 Ubicquia, Inc.

6.4

   Once fully inserted into the socket, 

rotate the UbiHub toward the 

pole to lock the NEMA connecter 

in place. Stop once the clamp is 

aligned with the pole.

6.5

   Close the clamp around the 

pole by rotating the clamp latch 

upward and securing with the 

swivel locking nut. Use the 1/2” 

deep drive socket to tighten the 

locking nut to 40 in-lbs torque.

NOTE:

 Make sure the NEMA plug 

and NEMA socket remain parallel 

during installation.

6.6

   Adjust the clamp vertically so 

that the device is parallel with the 

bottom of the luminaire to ensure 

there is no undue stress or strain 

on the NEMA socket.

6.7

  Once unit is parallel with the 

luminaire, tighten the vertical 

adjustment screws to 40 in-lbs 

torque using the 3/16” Hex bit.

6.8

   Tighten the horizontal adjustment 

screws to 40 in-lbs torque using 

the 3/16” Hex bit.

3/16”

3/16”

15°

1/2”

Содержание ubihub AP6

Страница 1: ...read this instructional guide completely and save for future reference 1 2 View of UbiHub parts from bottom Top Female NEMA Socket Swivel Locking Nut ALS Sensor Shuttles Dual Camera APAI Only Ground...

Страница 2: ...rrule end face cleaner Grounding clamp Additional length of grounding cable as needed 1 3 Package Contents UbiHub Unit with open cap attached Mounting Clamp Mounting Clamp Inserts x4 Dual Camera APAI...

Страница 3: ...rails are facing upwards 3 Preinstall Clamp 3 1 The mounting clamp mounts to a 2 IPS pole with optional inserts to accommodate for a 1 5 IPS or 1 25 IPS pole The mounting clamp can also be positioned...

Страница 4: ...ed or if installing multiple units on the same luminaire type set the clamp position using the reference dimensions on both the housing and clamp then tighten all adjustment bolts to 40 in lbs torque...

Страница 5: ...camera is shipped pre installed to the UbiHub unit via a cable Gently lift the unit from the shipping box ensuring the dual camera is removed as well Then flip the Ubihub over so the clamp is facing d...

Страница 6: ...il the N is positioned correctly pointed away from the luminaire pole Replace the two screws to secure the socket is in position B Loosen but do not fully remove the two side screws Then use a standar...

Страница 7: ...o tighten the locking nut to 40 in lbs torque NOTE Make sure the NEMA plug and NEMA socket remain parallel during installation 6 6 Adjust the clamp vertically so that the device is parallel with the b...

Страница 8: ...rotating inward Once in place ensure that the camera cable is not crimped or pinched AP6 Reinstall the clamp adjustment cover set aside in step 3 3 over the mounting clamp vertical adjustment screws b...

Страница 9: ...open the UbiHub rear access door 2 CAUTION Be sure to follow all applicable safety guidelines when handling SFP modules 7 1 The installer will need to select which grounding option to use based on lo...

Страница 10: ...nel A 3 Insert the SFP module into the SFP port designated on the UbiHub back panel A 4 Remove the gasket plug and seat the optical cable into the appropriate gasket opening B 2 Remove the gasket plug...

Страница 11: ...the Ubihub is now complete 10 Review Complete 9 Connecting IoT Accessories 9 1 The PoE port on the UbiHub allows any IoT device such as an additional camera or microphone to be installed and powered...

Страница 12: ...could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules Thes...

Страница 13: ...cording to the steps in this manual including use of relevant tools and equipment as required For example safety gloves device tether warning labels flash lamp helmet and or work clothes etc In the pr...

Отзывы: