manualshive.com logo in svg
background image

 

http://u-prox.com 

30

 

 

Panel programming 

Software 

Operation 

 

1. 

Determination  of  access  control  panel  mode: 
standalone or as part of ACS 

The"Configurator" 

Software- connect 

via USB port 

2. 

Setting  initial  parameters:  network  settings  of 
access control panel: 
a. 

Server  settings:  IP  address  or  DNS  name  of 
the  server,  access  ports  (port to  read,  port  to 
write) 

Don't proceed paragraph d. if DHCP used in the network.

 

b. 

Device  Settings:  IP  address  of  the  device  in 
computer  network,  subnet  mask,  IP  DNS 
server, gateway to the Internet 

ACS 

software 

 

3. 

Registration  and  activation  device  in  access 
control software (refer to ACS) 

4. 

Set up device with ACS software 
a. 

Configuring  access  points:  one-way  or  two-
way access point, Antipassback mode, time of 
entering PIN code (or off)  

b. 

Setting access direction: № of reader, time of 
doors  opening,  signs  of  "Alarm  Prohibited. 
Door  forced  open",  "Alarm  Prohibited.  Door 
opened too long" 

c. 

Setting of readers: reader type of 26 or 42 bit 

d. 

Setting  access  control  panel  input:  type  of 
reaction  and  pass  point  (e.g.  door  sensor, 
pass point A and B, or free pass, pass B) 

e. 

Setting  access  control  panel  output:  type  of 
use (block, siren, etc.), operating mode, pulse 
duration (if available in this mode), pass point 
that controls this output. 

5. 

By means of access control, the list is created with 
a  set  of  user  RF  IDs  and  their  additional 
parameters,  schedules,  rules  of  passage  through 
certain access points (refer ACS) 

6. 

After  forming  and  loading  the  configuration  from 
ACS software the device is ready for use 

 

 

 

Содержание IP400

Страница 1: ...1 001 Access control panel U Prox IP400 Installation and programming manual...

Страница 2: ...tment of external devices and panel configuration are described in Working with the device section Technical support To get warranty and technical support you can apply to authorized service centers s...

Страница 3: ...output 15 The communicator 15 Global antipassback 18 How to work with the device 20 Connection procedure 21 Installation recommendations 21 Connecting external readers 22 Connecting LoopControl 23 Re...

Страница 4: ...nt of non volatile memory U Prox IP400 is an access control system that provides for access control in variable establishments in small offices as well as on large enterprises with number of employees...

Страница 5: ...cts NO COM 1 A 24 V One USB port for network settings configuring for connection to ACS server Ethernet port 10BASE T 100BASE TX Adjusted with U Prox IP software Real time clock Antipassback Non volat...

Страница 6: ...ts one for entrance and the other one for exit door of this type is called double sided door A door with a reader on one side has only one Access point Entry point and it is called single sided door D...

Страница 7: ...appearance for this purpose System detects the global antipassback violation when somebody tries to re enter such area without exit or tries to enter somewhere from the area he have not enter System g...

Страница 8: ...panel is to be downloaded after all parameters are set modes of inputs outputs access rights and others During downloading parameters are rewritten into access control panel Description and operation...

Страница 9: ...http u prox com 9 Location of jumpers and removable pads with connectors on access control panel board and their function is shown in Fig 2 Fig 2 U Prox IP400 components...

Страница 10: ...lly disclosed 1 General NC2 normally closed Relay contacts 2 NO2 normally disclosed 2 General NO3 normally disclosed Relay contacts 3 3 Total NO4 normally disclosed Relay contacts 4 4 General 1BZ Buzz...

Страница 11: ...he network settings Jumpers Service TMP tamper contact FACT Factory reset Buttons But1 access point A RTE button But2 access point B RTE button Sound and light panel Yellow LED Standby mode periodic b...

Страница 12: ...ee pass has the highest priority as this mode is activated in the event of a fire followed by modes of Blocking Alarm and Normal in decreasing order of priority Normal mode This is the main mode of pa...

Страница 13: ...eeded and in case of RF ID matching attempt In Alarm mode panel activates outputs programmed as ALARM and SIREN Alarm output remains activated till Alarm mode is turned off For output SIREN siren time...

Страница 14: ...mputer or after loop violation designated as BLOCKING Access point is in Blocking mode for as long as the loop is violated or until the command from the computer while the loop is broken command from...

Страница 15: ...y order for several functions Blocking Siren Alarm Programmable output In addition there is programmable operation mode for each output start stop output remains active until the corresponding command...

Страница 16: ...events Waiting for server commands Algorithm of working on the Internet local wire net 1 If DHCP on IP is 0 0 0 0 obtaining of IP address within local network affiliate at panel launch 2 Update of sta...

Страница 17: ...ends data packages announcing access control system server about itself as a new device in the local network Despite it is broadcast announcement it is limited with single range local network and acti...

Страница 18: ...U Prox IP300 U Prox IP400 The basis of the global antipassback is the zoned antipassback The facility is divided into rooms zones of access or areas With this division the entrance to another area is...

Страница 19: ...n etc See Figure 7 Fig 7 Tracking the violations In case of lost communication with the access control panels forced entry free pass etc U Prox IC A merges access areas together considering that the p...

Страница 20: ...he U Prox IP software must be enabled antipassback mode General for the door For each access control dialog box must be specified master antipassback control panel and reaction to the deprivation of c...

Страница 21: ...h the loops in accordance with the sections below 11 Perform installation of the Ethernet cable into the connector terminal blocks 12 Place the top cover and fix it with screw 13 Connect the panel to...

Страница 22: ...Blue inclusion of buzzer signal Brown inclusion of red indicator Orange inclusion of green indicator Black GND Red 12 V Current consumption of each external reader connected to terminals 12 V should...

Страница 23: ...closing and opening Normal state of the loop from 1 4 kOm to 3kOm Line shortage less than 1 4 kOm the broken line more than 3 kOm It is recommended to use supplied resistors Request to Exit button RT...

Страница 24: ...Z4 terminals is on the Fig 13 Fig 13 Connecting door contacts Z3 and Z4 inputs function assigned as follows Z3 door contact of access direction A Z4 door contact of access direction B Program input as...

Страница 25: ...tact and RTE button of access direction B Any of 8 inputs can be assigned as a combined for service of door contact and RTE button Integration with the fire alarm system It is necessary to program the...

Страница 26: ...t of security control panel can be directly connected to this input When security alarm is on loop of access control panel designated as Blocking is broken All access points supervised by an access co...

Страница 27: ...o not allow long power supply For these latches program the lock time as short as possible to prevent coil overheating Assign relay outputs as outputs of locks at panel programming for proper operatio...

Страница 28: ...on data transmission to ACS server is initiated Panel provides protection against arbitrary interference due to the encryption of data with 256 bit key and against panel substitution supervising the u...

Страница 29: ...do not set if you use DHCP o IP address o Subnet Mask o IP address of the gateway router Internet 1 not necessarily in the local area network o IP address of the gateway router to the Internet 2 opti...

Страница 30: ...uring access points one way or two way access point Antipassback mode time of entering PIN code or off b Setting access direction of reader time of doors opening signs of Alarm Prohibited Door forced...

Страница 31: ...SB and configure the device using the software Configurator Replacing the device firmware 1 De power the panel 2 Remove the top cover of panel 3 Connect the notebook with USB cable to the panel 4 Usin...

Отзывы: