20
U-Prox IP100, U-Prox IP300, U-Prox IP400, NDC F18 IP access control dialog
boxes can be configured to two variants of behavior in case communication lost with
U-Prox IC A:
Not just anyone has permission to pass;
Pass all, according to the rules of the local antipassback
The requirements for U-Prox IC A adjusting:
The control panel must have a static address (IP or DNS)
The requirements for U-Prox IP100, U-Prox IP300, U-Prox IP400, NDC F18 IP adjusting:
Only control panels with double-sided doors (entrance and way out on
presentation of ID) can be involved in global antipassback.
In configuring server address # 1 has to be the ACS server address.
In configuring server address #2 has to be the address of the U-Prox IC A
In the U-Prox IP software must be enabled antipassback mode "General"
for the door
For each access control dialog box must be specified master antipassback
control panel and reaction to the deprivation of communication with him.
U-Prox IP100, U-Prox IP300, U-Prox IP400, NDC F18 IP control panels deliver
events to two destinations at the same time. First one is ACS server's address, to
display and store events in a database program. The second one is address of U-
Prox IC A. The Antippassback control panel sends an answer with command to den
у
or grant access.
How to work with the device
Before installation do initial setup of access control panel (that specifies settings of
network parameters) with utility "Configurator" via USB Port. Overall dimensions are
shown in Fig. 9
Fig. 9
. Overall dimensions
After ID presentation the delay in granting or denial of access may be up to 1
minutes, depending on the topology and bandwidth of the computer net