background image

U-Line Safety Precautions

1

IMPORTANT

IMPORTANT

• PLEASE READ all instructions before installing, 

operating, or servicing the appliance.

• Proper installation procedures must be followed when 

completing an installation or relocation of a unit. 
Consult the installation guide before any installation 
begins. U-Line contact information appears on the rear 
cover of this guide.

• This unit requires connection to a dedicated 15 Amp 

grounded (three-prong), polarized receptacle, installed 
by a qualified electrician, compliant with applicable 
electrical codes.

Safety Alert Definitions

Throughout this guide are safety items labeled with a Danger, 
Warning or Caution based on the risk type:

DANGER

Danger means that failure to follow this safety statement will 
result in severe personal injury or death.

WARNING

Warning means that failure to follow this safety 
statement could result in serious personal injury, 
property or equipment damage. 

CAUTION

Caution means that failure to follow this safety statement 
may result in minor or moderate personal injury, property 
or equipment damage.

2 Safety Precautions

General Precautions

Use this appliance for its intended purpose only and follow these 
general precautions with those listed throughout this guide:

DANGER

RISK OF CHILD ENTRAPMENT. Before you throw away your 
old refrigerator or freezer, take off the doors and leave shelves 
in place so children may not easily climb inside.

WARNING

SHOCK HAZARD - Electrical Grounding Required.
• Never attempt to repair or perform maintenance on 

the unit until the electricity has been disconnected.

• Never remove the round grounding prong from the 

plug and never use a two-prong grounding adaptor.

• Altering, cutting of power cord, removal of power 

cord, removal of power plug, or direct wiring can 
cause serious injury, fire and or loss of property and 
or life, and will void the warranty.

• Never use an extension cord to connect power to the 

unit.

• Always keep your working area dry.

WARNING

Install provided Anti-Tip kit on all Wine Captain 
Models and Beverage Centers. Serious personal injury 
could occur.

CAUTION

• Use care when moving and handling the unit. Use gloves 

to prevent personal injury from sharp edges.

• If your model requires defrosting, DO NOT use an ice 

pick or other sharp instrument to help speed up 
defrosting. These instruments can puncture the inner 
lining or damage the cooling unit. DO NOT use any type 
of heater to defrost. Using a heater to speed up 
defrosting can cause personal injury and damage to the 
inner lining.

IMPORTANT

IMPORTANT

• Do not lift unit by door handle.
• Never install or operate the unit behind closed doors. 

Be sure front grille is free of obstruction. Obstructing 
free airflow can cause the unit to malfunction and will 
void the warranty.

• Failure to clean the condenser every six months can 

cause the unit to malfunction. This could void the 
warranty.

• Allow unit temperature to stabilize for 24 hours before 

use.

• Do not Block any internal Fans

Use only genuine U-Line replacement parts. Imitation 
parts can damage the unit, affect its operation or 
performance and may void the warranty.

Содержание CLR2160

Страница 1: ...The Built In Undercounter Leader Since 1962 CLEAR ICE MODELS CLEAR ICE COMBO MODELS ICE COMBO MODELS U LINE COM CO1175 CO2175 CLR2160 CLRCO2175 INSTALL GUIDE CO29...

Страница 2: ...ment and Adjustment 6 Door Reversability 6 Reversing the door 6 Self Closing Doors Door Alignment and Adjustment 8 Door Reversability 8 Reversing the door 8 Door Panel Installation Custom 1 4 Thick Do...

Страница 3: ...cal Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two p...

Страница 4: ...Panel Kit Part number U OL2175B black units U OL2175W white units A complete water hook up kit is also available for purchase from your dealer Order U Line Part No WATERHOOKUP Exterior Cleaning Black...

Страница 5: ...lations CLR2160 Series Follow the cut out drawing The 15 1 4 width allows 1 4 for ease in installation and removal of the unit 24 is the cabinet depth in most installations 8 24 Minimum 24 1 4 See Ele...

Страница 6: ...16 34 3 16 15 15 Black and White Stainless Steel 23 1 4 3 7 8 23 1 4 3 15 16 Add 3 4 To Depth For Drain Line Clearance Add 3 4 To Depth For Drain Line Clearance CO1175 Series BLACK CO1175 23 5 16 34...

Страница 7: ...ments The units are designed to operate between 50 F 10 C and 100 F 37 C High ambient temperatures 100 F 37 C or higher may reduce the unit s ability to reach low temperatures and may also reduce the...

Страница 8: ...h black and white doors are field reversible Stainless steel models with glass doors without locks are field reversible Stainless steel models without glass doors must be ordered right or left hand hi...

Страница 9: ...ure to only remove the two screws holding the actuator to the door Reinstall the actuator 4 on the opposite end of the door where the nameplate was removed 8 Install new nameplate where the actuator a...

Страница 10: ...sets 3 Turn the door upside down and inspect the hinge plate mounting holes The plate has slotted mounting holes Loosen but do not remove the two hinge plate screws 1 4 If door edge opposite the hinge...

Страница 11: ...r inserts as shown on the new bottom hinge 4 Remove existing bottom hinge Remove the existing bottom hinge three screws 2 Reinstall hinge to top opposite Install the hinge just removed from the bottom...

Страница 12: ...tilting forward and lifting off bottom hinge pin 2 Pull door gasket out of groove top edge of door only Start in the middle and pull outward moving toward the edge This may take some force Model Width...

Страница 13: ...een placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit break...

Страница 14: ...n using the two wrenches Drain Connection CLR2160 CLRCO2175 IMPORTANT IMPORTANT Drain can NOT be located directly below unit Unit has a solid base that will not allow the unit to drain below itself We...

Страница 15: ...r cabinet or attempt to touch any components except the discharge tube during testing 4 Check that the clamps and hose connections are tight at the following areas Discharge tube A Drain tube B Vent t...

Страница 16: ...event of a pump failure It must have an operating temperature range of 50 F to 110 F 10 C to 40 C IMPORTANT IMPORTANT In the event of a power outage restricted drain or pump failure the failure to us...

Страница 17: ...st plugged into the electrical outlet Test the drain system by pouring one gallon of water into the ice bin The water should drain freely and there should be no leakage All Models 3 Gently push the un...

Страница 18: ...ution A The hinges should be self closing when the door is open approximately 8 If this is not the case make sure the closers at the bottom of the hinge pin are clean greased and installed correctly A...