PowerSeries - PC1616/PC1832/PC1864
16
6HFWLRQ>@)LIWK6\VWHP2SWLRQ&RGH
6HFWLRQ>@6L[WK6\VWHP2SWLRQ&RGH
6HFWLRQ>@6HYHQWK6\VWHP2SWLRQ&RGH
[4]
ON:
A valid user code must be entered to restore normal keypad operation after the blanking.
OFF:
Pressing any key will return the keypad to normal operation.
[5]
ON:
Keypad backlighting enabled.
OFF:
keypad backlighting disabled.
[6]
ON:
The system temporarily enables the Keypad Blanking feature if an AC failure is detected (to preserve the back up battery).
OFF:
The system will operate as normal.
[7]
ON:
The keypad turns
ON
the Bypass light if zones are bypassed while the system is armed.
OFF:
The Bypass light turns
OFF
when the system is armed.
[8]
ON:
The system supervises keypad tampers.
OFF:
The system does not supervise keypad tampers.
Option
Description
[1]
ON:
The system does
not
associate wireless keys to user codes.
OFF:
The system will assign user code 17 to wireless key #01, user code 18 to wireless key #02 etc. If the wireless key is used to
arm or disarm, the system will report the Opening or Closing for the associated User Code.
[2]
ON:
The system logs an RF Jam trouble condition if the condition is present for 5 minutes.
OFF:
The system logs the trouble condition after 30 seconds.
[3]
ON:
The keypads beep if an RF Jam trouble is detected.
OFF:
The trouble is not annunciated via the keypad buzzer.
[4]
ON:
The Double Hit feature will be enabled. Two violations from the same zone within the Cross Zone Timer will be considered a
valid Police Code or Cross Zone event. The system will report the event and log it to the event buffer.
OFF:
Two alarms from the same zone is not a valid Police Code or Cross Zone event. This feature is only available for the
following zone types; Interior, Interior Delay, Interior Stay/Away, Delay Stay/Away and Night Zone.
[5]
ON:
The system logs and communicates a
Late-To-Close
event when it auto-arms at the programmed time (not if auto arming was
caused by the No-Activity Arming feature).
OFF:
The system does not transmit or log a
Late-To-Close
event.
[6]
ON:
Enables the Daylight Savings automatic clock adjustment feature.
OFF:
The system does not automatically adjust the clock for Daylight Savings.
[7]
For Future Use
[8]
ON:
The system only squawks the bell output when the system is armed in the Away mode.
OFF:
The system squawks the siren when the system is armed in any mode (ee Section [14]).
Option
Description
[1]
ON:
The system only transmits a Test Transmission reporting code if no other event was transmitted to the central station during
the programmed time.
OFF
The system always transmits a Test Transmission reporting code as programmed.
[2]-[4]
For Future Use
[5]
ON:
The keypad buzzer follows the bell output for all alarms.
OFF:
The system only activates the bell output for all alarms.
[6]
ON:
When an alarm is detected on a zone (with the Cross Zone attribute enabled), a timer is started. The alarm is not transmitted
and the bell output is not activated unless a second cross zone enabled zone is violated before the Cross Zone timer times out.
OFF:
The system reports all alarms normally and logs and transmits a Police Code reporting code if a second zone alarm is
detected during the armed period.
[7]
ON:
The system restarts the Exit Delay (one time) if a Delay zone is violated and restored during the exit delay time.
OFF:
Exit delay does not restart.
[8]
ON:
The system activates the trouble beeps when an AC trouble is detected.
OFF:
The system does not annunciate AC troubles using the keypad buzzer.
Option
Description
[1]
ON:
The bell will sound for the duration of Bell Time Out if a wireless zone fault occurs while armed.
OFF:
Wireless zone faults will not sound the bell.