Section 4 Programming
This section provides the information necessary to program all required features for a basic system as well as common applications.
+RZWR3URJUDP
DSC recommends filling in the Programming Worksheet with the required programming information before programming the system. This
will reduce the time required to program and will help eliminate errors.
To enter Installer Programming press
[
][8][Installer Code]
. The Program light will FLASH (programmable LCD keypad displays will
change to
‘Enter Section’
). An error tone indicates the installer code entered is incorrect, Press
[#]
to clear any key presses and try again.
The default Installer Code is
[5555]
.
The Armed and Ready lights indicate programming status:
Armed Light ON
Panel waiting for 3-digit section number
If in module programming, waiting for section # to be entered.
Ready Light ON
Panel waiting for data to be entered
Ready Light FLASHING
Panel waiting for HEX data to be entered
You cannot enter installer programming while the system or any partition is armed or in alarm.
3URJUDPPLQJ7RJJOH2SWLRQV
Enter the 3-digit programming section number.
3URJUDPPLQJ'HFH[D(;'DWD
•
Enter the 3-digit programming section number.
•
The Armed light will turn
OFF
and The Ready light will turn
ON
.
•
Enter the data written in the boxes.
For sections that require multiple 2 or 3 digit numbers, the keypad will double-beep after each 2 or 3 digit entry and move to the next item in
the list. After the last digit in the section is entered, the keypad will beep rapidly 5 times and exit the program section. The Ready light will
turn
OFF
and the Armed light will turn
ON
.
For sections that do not require data for every box (such as phone numbers) press the
[#]
key to exit the program section after entering all the
required data. The Ready light will turn
OFF
and the Armed light will turn
ON
.
At any time the
[#]
can be pressed to exit any program section. All changes made up to that point will be saved.
In addition to the standard digits 0-9, HEX digits and special dialer functions can also be programmed if required.
+RZWR([LW,QVWDOOHU3URJUDPPLQJ
To exit installer programming, press the
[#]
key when the panel is waiting for a 3-digit section number (the Armed light is
ON
).
•
The Armed light will turn
OFF
and
•
The Ready light will turn
ON
.
•
The keypad will display which toggle options are
ON
or
OFF
according to the chart.
•
To toggle an option
ON
or
OFF
, press the corresponding
number on the keypad. The display will change accordingly.
•
When all the toggle options are configured correctly, press
the
[#]
key to exit the program section.
Keypad Type
Option ON
Option OFF
LED
Zone Light
ON
Zone Light
OFF
Fixed-Message LCD
Indicator
# ON
Indicator #
OFF
Programmable-Message LCD
#
Displayed
Dash
[-]
Displayed
•
The Ready light will turn
OFF
and the Armed light will turn
ON
.
HEX (or hexadecimal) digits are sometimes required. To enter a HEX digit, press
the
[
]
key to begin HEX programming. The Ready light will FLASH. Refer to the
chart at right and press the number corresponding to the HEX digit required. The
Ready light will continue to FLASH. Press
[
]
again to return to normal decimal
programming. The Ready light will turn
ON
.
Value
Enter
Telephone Dialer
HEX [A]
HEX [B]
HEX [C]
HEX [D]
HEX [E]
HEX [F]
Press [
][1][
]
Press [
][2][
]
Press [
][3][
]
Press [
][4][
]
Press [
][5][
]
Press [
][6][
]
Not Supported
Simulated
[
]
key
Simulated
[#]
key
Dial tone search
Two second pause
End of Number