Program the time the panel will wait between dialing attempts to transmit a reporting event to the central station.
Valid entries are
[001]
to
[255]
.
6HFWLRQ>@>@0RGXOH3URJUDPPLQJ
The following program sections are used to program different modules that can be connected to the control panel. Refer to the respective
Installation Manual for installation and programming information
[3]
ON:
The system will inhibit arming if a Low Battery or AC trouble condition is present.
OFF:
Arming will not be inhibited.
[4]
ON:
All Tamper troubles will latch and arming will be inhibited. Enter Installer Programming to clear the trouble condition and
return to normal operation.
OFF:
Tamper troubles will not latch and will not inhibit arming.
[5]
ON:
All access codes are 6 digits long.
OFF:
All access codes are 4 digits long.
[6]
ON:
The system will hang up if a busy tone is detected. This attempt is not counted towards the
Maximum Dialing Attempts
programmed.
OFF:
The panel will not detect busy tones.
[7]
ON:
The system will charge the battery at approximately 700mA.
OFF:
The system will charge the battery at 400mA.
[8]
ON:
The system will abort a DLS session, Escort access, Listen In/Two-way session if a new central station communication event
occurs.
OFF:
Non-critical events (Test transmission, Periodic Test and System Test) will not abort the session. Events will be
communicated after the session is complete.
Option
Description
[1]
ON:
The communicator uses 33/67 make/break ratio when pulse dialing.
OFF:
The system uses 40/60 make/break ratio.
[2]
ON:
The system dials regardless of the presence of dial tone after the first attempt.
OFF:
The system dials only if dial tone is detected.
[3]
ON:
changes the Test Transmission Cycle Time to minutes.
OFF:
Sends a Test Transmission after the programmed number of days.
[4]
ON:
The system accepts 1600Hz handshake pulse formats.
OFF:
The system accepts 1400Hz or 2300Hz handshakes.
[5]
ON:
The system generates a tone for 500mS every 2 seconds indicating digital equipment is making the call vs. a voice call.
OFF:
The system does not generate a tone.
[6]
ON:
The tone generated (2100Hz.) indicates that digital equipment is making the call.
OFF:
The tone is 1300Hz.
[7]
ON:
The DLS downloading window is 1 hour.
OFF:
The DLS downloading window is 6 hours.
[8]
ON:
The system activates the bell output if a
Failure to Communicate
trouble occurs while the system is armed.
OFF:
The system does NOT activate the bell output if a Failure to Communicate trouble occurs while the system is armed.
Section [801] PC5400 Printer Module Programming
Section [802] PC59xx VOX Module Programming
Section [803] Alternate Communicator Programming
Section [804] Wireless Programming
Section [805] PC5100 Addressable Programming
Section [851] T-Link Communicator Programming