3.5.14 Wrap the spiral tube around the ribbons.
3.5.15 Put a strip of foam around the spiral tubes and strap them with
a tie-wrap to the tray.
3.5.16 Arrange the ribbon fibers in the tray for storage.
Note: pictures show the maximum (24 ribbon, 12 loops) amount
of ribbons stored, in this case no splicing is allowed. Splice holders
can be removed of the tray.
•
If splicing of both ends has to be done later, put only 12
ribbon-12 loops at the tray (or 6 ribbon - 24 loops).
•
If splicing of only one end has to be done later, maximum
capacity should be 24 ribbon-12 loops (or 12 ribbon - 24
loops).
•
If no splicing needs to be done, a maximum of 48 ribbon-12
can be stored (or 24 ribbon-24).