Use  the 2 outer  leg
for  dual SM attachment

bend down  middle legs

3.3.1

Cut the strength member(s) at 32 mm.

Note

: if shield is present, attach the bond wire to the sheath.

Use fork middle leg
for central SM attachment

bend down  2 outer legs

Loose tube

3.3.3

For 

central strength members

, use the fork middle leg.

Slide the strength member into the strength member termination and

tighten the screw. Bend the fork outer legs out of the way.

Note

: For large central strength members, use the larger square bolt

(only in 3 port kit).

3.3.2

Install the strength member termination onto the strength

member attachment forks depending the cable type.

3.3.4

For 

dual strength members

, bend the fork middle leg

out of the way and use the two outer legs. 

3.3.5

Install the strength member bracket into the cable

attachment assembly by pushing the metal tab into the slot.

3.3.6

Adjust the sheath retention clips until they grip the cable

sheath. Wrap a hose clamp around the sheath retention clips and

cable, secure the hose clamp.

Note

: make sure that the hose clamp bolts are to the side of the

cable and will not be trapped between the cables and closure or

interfere with upper cable attachments.

3.3.7

Install top cable attachment assembly and secure with

the removed two pins. Repeat steps 3.3.2-3.3.7 if cables are

installed in the top ports.

Central core - Ribbon

Содержание FOSC-600 C

Страница 1: ...buried and aerial applications The FOSC 600 closure uses compressed gel cable seals The closure can contain up to nine single fusion trays with a slack basket or up to six ribbon trays with no slack...

Страница 2: ...l cable seal port plugs Slack basket Plastic bend control Cable attachment assembly Hose clamps Closure mounting brackets Bond wires ID label cards Gel seal lubricant Transportation tube Cleaning tiss...

Страница 3: ...has to match the small slot in the seal cavity see arrow 3 1 8 Insert the rubber seal in the groove starting at the open port Note do not stretch the seal 3 1 9 If the seal is too long at the end cut...

Страница 4: ...If both the lower large ports are filled with the maximum cable diameter 28 mm the maximum cable diameter in the upper small ports becomes 20 mm 3 1 13 Position the gel block tabs in the open slots w...

Страница 5: ...o the strength member attachment forks depending the cable type 3 3 4 For dual strength members bend the fork middle leg out of the way and use the two outer legs 3 3 5 Install the strength member bra...

Страница 6: ...t and slide the FOPT approximately 50 mm over the loose tube 3 5 Fiber routing 3 5 1 Do not route directly to the splice trays pass around the tower For in line applications it is recommended not to u...

Страница 7: ...routed under the basket 3 5 8 Secure the spiral tube coming from the cable to the basket Insert the FOPT 50 mm inside the spiral tube and secure it to the basket Route the FOPT as shown Central core...

Страница 8: ...Put a piece of teflon tape at 1 2 meter on the straightened ribbon bundle Note the 1 2 meter is measured from the basket entrance side were tray holder is B Loop storage on trays 3 5 12 Take appropri...

Страница 9: ...4 ribbon 12 loops amount of ribbons stored in this case no splicing is allowed Splice holders can be removed of the tray If splicing of both ends has to be done later put only 12 ribbon 12 loops at th...

Страница 10: ...n the tray in an orderly fashion as shown on the drawing Note Store the ribbons as much as possible in bundles Avoid crossings 3 6 Fiber splicing and capacity FOSC 600 C Can contain up to 5 single fus...

Страница 11: ...for routing the tubes to the trays The basket is shipped in the correct position for butt configuration For in line configuration an adjustment must be made to the basket 3 7 3 Install a spacer as sh...

Страница 12: ...by inserting a screwdriver into each latch Check the bolts again to make sure they are tight 3 8 6 In the ports which are not used install a plug 3 8 Closing the closure 3 8 3 Make sure that the latc...

Страница 13: ...r clockwise Insert a screwdriver through the loop of the trigger to apply extra torque if required 3 9 2 Unlatch each of the latches in order using a screwdriver Hooks must be completely disengaged an...

Страница 14: ...14 B Pole mounting Aerial mounting brackets sold separately...

Страница 15: ...15...

Страница 16: ...y is believed to be reliable However Tyco Electronics makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use Tyco Electronics obligations shall o...

Отзывы: