![Tyco Electronics FOSC-600 C Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/tyco-electronics/fosc-600-c/fosc-600-c_installation-instructions-manual_1186145004.webp)
4
3.3
Cable preparation and installation
3.3.1
Remove the outer jacket:
Loose buffer tube:
Drop : 2,10 m
Loop : 4,20 m
Ribbon:
Drop: 2,10 m
Loop: 4,20 m
LBT Ribbon:
Drop : 2,10 m
Loop: 4,20 m
Central core:
Drop : 2,10 m
Loop: 4,20 m
3 and 4-way gel block
3-way gel block
Upper Small Ports: 2 ports 8 - 20 mm
Lower Large Port: 1 port 28 - 35 mm
4-way gel block
Upper Small Ports: 2 ports 8 - 22 mm
Lower Large Ports: 2 ports 10 - 28 mm
If both the lower large ports are filled with the maximum cable
diameter (28 mm), the maximum cable diameter in the upper
small ports becomes 20 mm.
3.1.13 Position the gel block tabs in the open slots with the
trigger outside the closure. The larger ports in the gel block are in
the bottom of the closure. Fill bottom ports with larger diameter
cables, then fill top ports with small diameter cables.
3.1.11 Remove the top half of the cable attachment assembly by
removing the two pins.
1.
2.
3.1.12 Secure the bottom part of the cable attachment assembly in
the closure with two screws.
3.2
Cable types and sizes
Содержание FOSC-600 C
Страница 14: ...14 B Pole mounting Aerial mounting brackets sold separately...
Страница 15: ...15...