Page 5
2.
Installation and
commissioning
2.1
Mounting
In the back of the manifold there are 2
threaded M10 x 15mm holes for wall
mounting. See (Appendix A).
Optionally, a foot-mounting bracket is
available.
2.2
Connections
Hydraulic pressure ports out of the manifold
are G1/4” or G1/2”. All connection points are
plugged with VSTI-plugs.
All pipes, hoses, fittings etc. mounted to the
total system, should be flushed to meet the
demands of NAS 1638 Class 8 or ISO 4406
Class 19/17/14.
2.3
Before starting the pump unit
The power unit may have been sent without
nitrogen gas (N2) in the accumulator,
depending on global or local regulations for
transport of pressurised equipment. If the
unit has been sent without pressure, a label
(see figure 2.1) is attached to the
accumulator.
If the accumulator is not pre-charged it must
be charged before usage. See section 4.11
– “Recharging the accumulator”.
After recharging you should remove the
label.
If the accumulator is pre-charged
– proceed
to section 2.3.1
Mount the connection fitting to the brakes in
one of the points shown on the hydraulic
diagram
2.3.1
Fill the tank with oil of the recommended
quality (see Appendix E).
The oil fill volume is approximately 3 litres.
Remove the air breather (5b), and add
filtered oil.
2.3.2
Fill the oil reservoir to the top level mark in
the sight glass located on the reservoir
sidewall.
CAUTION
Use only filtered oil of the right viscosity for
refilling (see Appendix E).
NOTE:
Stated oil volumes are approximate and
must be checked for correct fill level
according to the sight glass in the tank.
Additional oil volume may be required for
bleeding.
Oil must be filtered through a 10-micron
nominal filter.
For more details see Appendix E.
2.3.3
Connect the electrical power. Check that the
rotation of the electric motor is correct as
indicated on the motor
– i.e. Counter
clockwise viewed from the fan end.
WARNING
External electrical cables must be connected
to the junction box according to the electrical
wiring, diagrams see Appendix D, or
separate documentation supplied along with
the equipment.
The unit must only be connected by a skilled
electrician.
FIGURE 2.2
FIGURE 2.1
FIGURE 2.3