6.6 Terminal Block Connection
TSOL series inverter is equipped with multiple terminals to meet the extra needs of the
user as below:
①
Turn off the switch to shut down the inverter remotely.
②
&
③
Instruct the generator to start generating power when the batteries are (almost)
empty.
(
DO
)
○
4
&
○
5
Connect the battery temperature sensor (for lead acid batteries only). When the
battery temperature exceeds the allowable range, battery charge and discharge
will be prohibited.
○
6
&
○
7
RS485 communication terminals.
6.7 WiFi Connection
Inverter provides a WiFi port which can collect data from inverter and transmit it to
monitoring-website via a Pocket WiFi. (Purchase the product from supplier if needed)