41
Date Time
2019-01-01
00:00
-OK-
7.4.2 safety
User can set safety standard according to different countries and grid tied standards.
Safety
VDE 0126
-OK-
7.4.3 export limit power
User can set the power value to
allows the inverter able to control energy. The value range
from 0 to 6000.
Export Limit
5000W
-OK-
7.4.4 battery parameters
The Battery parameters setting contains five items: battery type, battery capacity (AH),
constant charge voltage, max soc (only for lithium)/charge cut-off volt age (only for lead crystal),
min soc (only for lithium)/discharge cut-off voltage (only for lead crystal).
Note:
Current support PYLON US2000 high voltage lithium battery and lead crystal battery.
Battery Type
PYLON-H
-next-
7.4.5 work mode
There are five work modes for user choice. Self Use(default), Forc e Time Use, Back Up Mode,
Feed in Priority, Peak Valley Mode. Users can choose the appropriate mode according to their
own needs.
Work Mode
Self Use
-OK-
After all the above parameters are set up, the inverter starts to run.