29
Note: When working with Pylontech batteries, it is recommended the number of battery
module (H48050-15S) is 2-7 and the number of battery manager system (SC0500A-100S)
is 1.
BMS PIN Definition
Communication interface between inverter and battery is CAN with a RJ45 connector.
Power Connection Steps:
Step1.
Choose the 9 AWG wire and strip the cable to 15mm.
Step2.
Insert the stripped cable up to the stop (negative cable for DC plug - and positive
cable for DC are live). Hold the housing on the screw connection.
Step3.
Press down spring until it clicks audibly into place (it must be possible to see the
fine wire strands in the chamber).
Step4.
Tighten the screw connection (tighten torque: 2.0Nm).
Step5.
Plug the battery connectors into the corresponding battery connectors on inverter.
PIN
1
2
3
4
5
6
7
8
CAN
Definition
x
GND
x
BMS_CANH BMS_CANL
x
x
x
Note
!
The battery communication can only work when the battery BMS is
compatible with the inverter.