CONVERSION INSTRUCTIONS
TO BE COMPLETED BY AN AUTHORISED PERSON
ENSURE GAS IS ISOLATED WHILST PERFORMING
CONVERSION WORK. PERFORM A LEAK TEST BEFORE
IGNITING AND MAKING BURNER AND PILOT
ADJUSTMENTS.
TO PROPANE GAS
Regulator
Change regulator to PROPANE gas configuration
and adjust as necessary.
Burner Injectors
Access and change the injectors to PROPANE Gas
injectors
(refer Nominal Gas Consumption
Table)
.
LEAK TEST IN ACCORDANCE WITH APPROVED METHODS
Ignite burners and adjust.
AMEND DATA PLATE AND APPLY ‘PROPANE’ GAS LABEL
TO NATURAL GAS (NG)
Regulator
Change regulator to NG gas configuration and
adjust as necessary.
Burner Injectors
Access and change the injectors to NG Injectors
(refer Nominal Gas Consumption Table).
LEAK TEST IN ACCORDANCE WITH APPROVED METHODS
Ignite burners and adjust.
AMEND DATA PLATE AND APPLY ‘NATURAL GAS’ LABEL.
Salamander Manual
Page 19
Revision: 13 Sep 07
OPERATOR MANUAL S86 130907.doc