BURNER ADJUSTMENTS
Leak Test
•
Ensure that all valves are in the OFF position.
•
Turn on the main gas supply valve.
•
Light the burners.
•
Leak test all valves and fittings using approved methods.
•
Correct any leaks as required and re-check.
•
Shut off all valves and set controls to the “OFF” position.
Test Point Pressure
The test point is located on the gas manifold. The gas manifold and pressure
test point is accessed by removing the gas valve control knobs and the front
panel. The test point pressure is shown in the Nominal Gas Consumption
Table and is
set with the two burners operating at maximum setting.
Burner Adjustment
The burner orifices are fixed as specified and cannot be adjusted. The
specified gas rate will be achieved if the gas supply pressure and test point
pressure is correct and all gas components are clean and free of blockages.
The turndown (low flame) setting can be adjusted by adjusting the screw on
the gas valve.
A distinct blue flame over the entire port area of the burner will be achieved at
full rate when the air supply is correct.
If the flame is yellow and wavy, the cause needs to be established.
WARNING:
If you are not competent in performing any service task or require
assistance, please contact Comcater Service 03 8369 4600.