SERVICE
FOR YOUR SAFETY, ALL SERVICE WORK MUST BE
CARRIED OUT BY AN AUTHORISED PERSON AND USE
ONLY ORIGINAL SUPPLIED AND SPECIFIED PARTS.
TEST ALL FITTINGS, PIPES AND PIPE CONNECTIONS FOR
LEAKS IN ACCORDANCE WITH APPROVED GAS LEAK TEST
PROCESSES AND METHODS. DO NOT USE A FLAME.
Note: When checking gas test point pressure, ensure that all other
equipment on the same line is turned ‘ON’ and operating.
RECOMMENDED SERVICE
It is recommended that an authorized person service your appliance every 12
months. This period is for guidance purpose only and may vary based on
usage of the equipment and operator care. Prescribed service tasks include;
•
Functional test of all components and clean, lubricate and adjust as
necessary.
•
Inspect and clean all gas valves and lubricate with an industry approved
lubricant.
•
Inspect all gas piping.
•
Check and adjust specified gas pressures.
•
Leak
test.
•
Full operational, performance and safety test.
SERVICE INFORMATION
•
To access gas valves, remove control knobs and the front panel.
•
To remove a gas valve, disconnect the gas valve at the manifold tee
spigot connection and remove the valve.
•
To access thermocouples, release the thermocouple from the ignition
block (spring clip) or remove the top of the unit.
•
To access burners, remove the top panel, undo the retaining screw,
remove the piezzo ignition lead, release the thermocouple from the
ignition block (held by spring force), lift up the burner and pull forward –
re-assemble in reverse order.
Salamander Manual
Page 17
Revision: 13 Sep 07
OPERATOR MANUAL S86 130907.doc