![Trueheat Salamander S86 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/trueheat/salamander-s86/salamander-s86_installation-operation-and-service-manual_1175597012.webp)
SALAMANDER BURNERS
Salamander Burner Control
WARNING: Ensure there are no objects placed on top of the unit and that
there are no restrictions to the flue passages.
NOTE: Ensure the gas supply to the equipment is turned ON
SALAMANDER BURNER IGNITION
Starting from the OFF
●
position, turn the control knob to the LEVEL 1 position.
Fully depress the control knob and then press the piezzo igniter to ignite the
burner – repeat until the burner ignites. Keep the knob fully depressed for 15
seconds after the burner lights. When the automatic valve senses that the
BURNER is alight, the gas flow to the burner will continue when the knob is
released. The equipment may then be operated between LEVEL 1 position
(highest heat) and LEVEL 2 (lowest heat).
NOTE: When the equipment is cold, the gas properties are such that it is
likely to be easier to light the burner (at the front or the side) with a gas
torch rather than the piezzo igniter as per the above process.
WARNING: NEVER PLACE YOUR HAND UNDER THE BURNER.
Shut Down
Turn the control knob to the OFF
●
position.
NOTE:
If the burner flame were accidentally extinguished, the flame failure
safety device would operate and cut the gas flow to the main burner. It would
then be necessary to re-light the burners by following the above procedure.
Salamander Manual
Page 12
Revision: 13 Sep 07
OPERATOR MANUAL S86 130907.doc