BE-LCD-01 Operating and Installation Manual / Leaflet no. M375EV8 (01/2015)

2

1 General information __________________ 3

Other applicable documentation ________ 3
Symbols used in this manual ____________ 3

2 Safety and correct use ________________ 4

General information regarding safety ______ 4
General safety measures ______________ 4
Correct use ________________________ 4
Incorrect use ________________________ 4
Residual risks ______________________ 4

3 Product description  __________________ 5

Product overview and dimensions ________ 5
Functional description and technical data __ 6

4 Transport, storage and packaging ________ 7
5 Operation · Fume cupboard control ______ 7

Fume cupboard control ________________ 7
Basic functions ______________________ 8
Additional functions __________________ 9
Operating mode default setting __________ 9
Automatic sash device ________________ 10
Fume cupboard lighting ________________ 10
Overriding operating mode defaults set 

by the central BMS____________________ 10
Operating states, alarm messages, 

fault displays ________________________ 11

5 Operation · Room control ______________ 14

Room control ________________________ 14
Basic functions ______________________ 15
Additional functions __________________ 16
Operating mode default setting __________ 16
Overriding operating mode defaults set 

by the central BMS____________________ 17
Operating states, alarm messages, 

fault displays ________________________ 18
Mounting __________________________ 21

6 Installation and electrical wiring __________ 21

Mounting on an adapter ________________ 22
Wall installation using a junction box ______ 22
Installation to a wall or to furniture ________ 23

7 Commissioning ______________________ 24
8 Maintenance ________________________ 24

Contents

TROX GmbH

Heinrich-Trox-Platz 

D-47504 Neukirchen-Vluyn
Phone +49 (0) 28 45 20 20 

Fax

+49 (0) 28 45 20 22 65

E-Mail [email protected] 

www.troxtechnik.com

Subject to change / All rights reserved © TROX GmbH

Содержание EASYLAB BE-LCD-01

Страница 1: ...ating and Installation Manual Leaflet no M375EV8 01 2015 The art of handling air The art of handling air Operating and Installation Manual EASYLAB Control panel BE LCD 01 for fume cupboard control and...

Страница 2: ...Fume cupboard lighting ________________ 10 Overriding operating mode defaults set by the central BMS____________________ 10 Operating states alarm messages fault displays ________________________ 11 5...

Страница 3: ...lation manual before starting any work and to comply with it The manual must be given to the facilities manager when handing over the system The facilities manager must include the manual with the sys...

Страница 4: ...reign matter if any If the device emits a smell or smoke have it checked by the manufacturer 4 BE LCD 01 Operating and Installation Manual Leaflet no M375EV8 01 2015 2 Safety and correct use Correct u...

Страница 5: ...green yellow red with text HIGH and LOW Connection socket for service and commissioning device Acoustic alarm acknowledgement Manual control Selection of operating mode Lighting or other equipment RM...

Страница 6: ...tion One button for the fume cupboard lighting One button for manual control Service socket The range of functions of the control panel can be adapted to project specific requirements using the EasyCo...

Страница 7: ...udes BE LCD 01 control panel with adapter Connecting cable approx 5 m patch cable blue Operating and installation manual Transport on site If possible take the control panel in the transport packaging...

Страница 8: ...of fume cupboard operating states and faults Display texts p 11 onwards The display of additional information can be configured Volume flow rate setpoint and actual values Face velocity actual value o...

Страница 9: ...me flow will then automatically be deactivated after the set delay Additional functions Depending on the configuration and operating mode default setting additional displays and function buttons may b...

Страница 10: ...ny other operating mode on the control panel This operating mode default setting can be terminated by pressing the manual control button again The fume cupboard controller then resumes the previous op...

Страница 11: ...e controller configuration the damper blade will remain open or will be shut shut off SC Automatic sash device Error message relating to the automatic sash device S1 Test function The general test fun...

Страница 12: ...f controllers 24 More than 24 controllers have been connected to the communcation cable Reduce the number of controllers C3 Communication cable termination The communication cable has not been termina...

Страница 13: ...supportive flow fan Control panel faults Code Message Explanation Actions remedial measures E1 Connection lost Communication between the control panel and the fume cupboard controller has been interru...

Страница 14: ...oard 1 Fume cupboard n Supply air Extract air Communication cable The BE LCD 01 control panel is used to display and control the most critical aerodynamic and safety related functions of an EASYLAB co...

Страница 15: ...and actual values The display can be adjusted using the configuration software BE LCD 01 Operating and Installation Manual Leaflet no M375EV8 01 2015 15 5 Operation Room control Volume flow rate cont...

Страница 16: ...This enables an automatic deactivation of the increased operation after the set delay Note Whether a defaulted operating mode applies to a controller in a room depends on the configuration of the cont...

Страница 17: ...an then set any other operating mode using the control panel To resume the previous operating mode from the central BMS press the manual mode button again Manual operation can be set for a limited per...

Страница 18: ...ic signal Alarm messages Code State Explanation Actions remedial measures A1 Volume flow rate too high The volume flow rate exceeds the setpoint value Check the actuator and the controller A2 Volume f...

Страница 19: ...either no differential pressure controller on the communication cable or the room management function is not active Include a differential pressure controller Activate differential pressure control i...

Страница 20: ...ler has been interrupted For technical reasons this text always appears in English Check the cable connection the control panel and the controller E2 CP CRC failure Communication between the control p...

Страница 21: ...e for mounting the control panel onto an adapter Danger Danger of electric shock Do not touch any live components Electrical equipment carries a dangerous electrical voltage during operation Only skil...

Страница 22: ...nto place See picture on p 23 5 Align the control panel including the cable with the adapter and press it onto the fixing points until it locks into place In the process carefully push the connecting...

Страница 23: ...to the right 5 Align the control panel including the cable with the base plate and press it back onto the base plate until it locks into place In the process carefully push the connecting cable back...

Страница 24: ...alarm in case the sash is opened beyond the maximum operational sash opening Enabling the function button for Increased Operation Enabling the function button for Reduced operation Enabling the funct...