background image

Installation and user guide- 4 

3   Quick Start Guide  

 
INSTALLATION 
 

 

Insert the batteries in your fall detector. (cf. §5.1) 

 

 

Position the rigid tube. 

 

 

Put in place your detection device on the edge of your pool at the proper place being careful 
about the immersion depth of the tube: 8,5 in (+/- 1 in). Cut the rigid tube at the proper length 
if necessary. (cf. §5.2) 

 

 

Perform a fall test : Simulate somebody falling into the pool by dropping a 2.5 US gallons jerry 
can full of water (in order to weight 18 lbs) off the edge of the pool – the siren must sound a 
maximum of 20 seconds after the fall. (cf. §5.3) 

 

 

Stop the siren by entering your password (Initially 1234). 

 

 

Wait for the reset of the product in “ALARM”  mode during 20mn  max. (The 

 LED starts to 

blink in green). 

 

 

Immobilize  the  TRITON

TM

  alongside  the  edge  of  the  pool  with  the  supplied  fixation  kit.  Your 

device is now operational. (cf. §5.4) 

 
UTILISATION

  

All the LED indicate independent states. 

 

SIGNAGE 

ACTIVATION CODE 

IDENTIFICATION 

LED 

 : 

 

(blinks in green quickly) 

One high tone sound: PIP 

11 or 22 or 33 or 44 

(A double hit on any key) 

« DETECTION » mode 

LED 

 : 

 

(blinks in red quickly) 

One low tone sound: BURP 

1234  

(or the password you entered) 

« INACTIVE DETECTION » mode 

LED 

 : 

 

(still) 

122344 

1111 

« PASSWORDCHANGE» mode 

(manual mode code followed by 

password change) 

LED 

 : 

 

(blinks once in green) 

One high tone sound: PIP 

Any good entry 

 GOOD ENTRY  

LED 

 : 

 

(blinks once in yellow) 

One low tone sound: BURP 

Any wrong entry 

BAD ENTRY  

LED

 : 

 

(blinks in red quickly) 

One low tone sound: BURP  

(Once every minute) 

None 

“LOW BATTERIES” mode 

Please replace the batteries as soon as 

possible 

Содержание TRIT001-US

Страница 1: ...OFF mode 17 7 8 Replacing the batteries 18 7 9 I have an issue with my falling detector 18 8 FAQ Frequently asked questions 20 9 Warranty and after sale services 23 10 Monthly Tests 24 FCC REGULATION...

Страница 2: ...subsurface pool device which detects the fall of an 18 lbs child by providing automatically sounding an alarm This device is not intended to replace any other safety consideration that is adult superv...

Страница 3: ...n unit with a black hose 1 rigid tube with attachment screws 1 remote alarm system 4 1 5V LR20 alkaline batteries supplied 1 AC DC Adapter 110V 12V for the remote system 1 fixing kit screws washers ta...

Страница 4: ...M mode during 20mn max The LED starts to blink in green Immobilize the TRITON TM alongside the edge of the pool with the supplied fixation kit Your device is now operational cf 5 4 UTILISATION All the...

Страница 5: ...totally still Then it goes back to DETECTION mode Be patient because this can take more than 10 minutes to happen NEVER LEAVE THE POOL UNATTENDED IN THIS MODE o In case of high winds the device can t...

Страница 6: ...ODE To reduce your reaction time TRITON includes a remote alarm system with a radio receiver which can be set up near your living room or other convenient location This will also sound a siren in case...

Страница 7: ...N THIS MODE INACTIVE DETECTION LED blinks in red quickly To switch to this mode From the INACTIVE DETECTION mode type the password initially 1234 The siren CAN emits a 85 dB signal at 10 feet when tri...

Страница 8: ...8 Default Signage Default Signage LOW BATTERIES LED blinks in red quickly One low tone sound once in a minute BURP HARDER DEFAULTS the device requires maintenance LED LED LED all the LEDs are blinkin...

Страница 9: ...ng ones are incompatible with falling detector systems The proper performance of TRITON is not correctly achieved if used in parallel with tarpaulins WARNING TRITON is kitted up with a powerful siren...

Страница 10: ...he siren is audible from the inside of your house Your falling detector should be placed in the middle of the largest length on a brink recommended position for rectangular shaped pool If your pool do...

Страница 11: ...ode facultative In this mode the siren is attenuated and stops by itself after 5 seconds See chapter 7 5 page X for more details For these tests TRITON should be in DETECTION mode the LED blinks in gr...

Страница 12: ...d with care to guarantee the waterproofness and the good operating state of your device Check that the 2 main black joints are correctly positioned in their location on the base Put back in place the...

Страница 13: ...te siren you should synchronize the two devices a Choose a location for your remote device o 70 feet away max from the TRITON o Near an electrical plug b Plug the power supply to the remote siren IMAG...

Страница 14: ...mmended to place the siren as high as possible on your wall pay attention to the power supply wire IMAGE 5 o Insert the 2 tapping inserts in the 2 new holes o Screw down the 2 screws through the siren...

Страница 15: ...avoid the formation of algae in the probe In case of restart of your falling detector after an extended stop please proceed the tests explained in 5 4 In case of issue please contact immediately your...

Страница 16: ...oved In that case your device understands your request by responding with a high tone sound PIP but can t restart immediately the monitoring The LED blinks in red It will progressively start the monit...

Страница 17: ...s slowly in yellow and a high tone sound is heard PIP Enter the password change code 1111 the mode will be validated by the LED blinking once in green and a high tone sound PIP Enter your new password...

Страница 18: ...off the TRITON see 7 6 upper Remove with care the 4 caps with the help of a flat screwdriver Unscrew the 4 screws and remove the cover Remove the used batteries Place the new batteries in their locati...

Страница 19: ...e us to give you a quick answer please give us a short description of the problem Please send our technicians your address and a quick drawing of your swimming pool with its dimensions length width de...

Страница 20: ...t substitute for parents watchfulness and or responsible grown up which remains the essential factor for 5 years old children safety It substitutes neither to horse sense nor to individual responsibil...

Страница 21: ...from the pool or alert adults to their presence For more information contact the Association of Pool and Spa Professionals www TheAPSP org This alarm does not replace responsible adult supervision Wh...

Страница 22: ...risk of a cold shock response How to rescue a child from the pool 1 Extend a long object such as a pole shepherd s hook or towel and pull in the child or throw the child a floating object 2 If the ch...

Страница 23: ...r failures resulting from an accident shock negligence or misuse a failure or defect in the electrical supply in an external electrical circuit lightning the use of parts not supplied by ABTYS and una...

Страница 24: ...passed failed 7 Test achieved the 8 Test achieved the Passed failed passed failed 9 Test achieved the 10 Test achieved the Passed failed passed failed 11 Test achieved the 12 Test achieved the Passed...

Отзывы: