background image

Installation and user guide- 16 

7.2  Automatic reset 

 

Your  falling  detector  keeps  on  checking  the  agitation  state  of  the  pool.  As  soon  as  the  pool  is 
sufficiently quiet, after a swim or a strong perturbation (strong wind, upriver swimming system …) 

your  falling  detector  switches  automatically  to  REACTIVATION  mode  (the  LED 

  : 

blinks in green / red). The fall detector is active but downgraded. 

 

As  soon  as  the  pool  is  fully  quiet,  your  falling  detector  switches  automatically  to  “DETECTION” 

mode(the LED 

 : 

blinks in green). This could take more than 10 minutes. 

 
Your pool is now secured. 
 
WARNING:  It  is  possible  that  the  device  changes  to  DETECTION  mode  if  you  are  in  the  pool 
without making any disturbances.  

7.3  Manual reset 

 

After a swim, you can signal to your falling detector that your pool is let unused, in order for it to 

restart the monitoring faster. 
You are in one of the 3 cases below: 

Commoved pool:

 Cas

e

 1

 

 

Lightly commoved pool: Case 2 
Quiet pool: 

Cas

e

 

3

 

 

Press twice on any key while leaving the pool. 

 

Case 1:  Your  falling detector  measures  that your  pool is  too  commoved.  In  that  case,  your  device 
understands your request by responding with a high tone sound (PIP) but can’t restart immediately 

the  monitoring.  The  LED 

  :

 

blinks in  red.  It will  progressively  start the  monitoring  as  the 

pool becomes quiet. 

 

D

URING THIS PERIOD

,

 A RESPONSIBLE ADULT

/

GROWN UP 

MUST

 KEEP WATCHING OVER THE POOL

 

Case 2: Your falling detector measures that your pool is lightly commoved. In that case, your device 
understands  your  request  by  responding  with  a  high  tone  sound  (PIP)  and  restarts  monitoring  but 

can’t  guarantee  the  detection of a  8kg  fall. The LED 

 :

 

blinks  once in  red followed  by  a 

green blink and so on. It will progressively start the monitoring as the pool becomes quiet. 

 

D

URING THIS PERIOD

,

 A RESPONSIBLE ADULT

/

GROWN UP 

MUST

 KEEP WATCHING OVER THE POOL

 
 

Case 3: Your falling detector considers that your pool is quiet. It restarts the monitoring by switching 

the LED 

 : 

in green and validating the choice with a high tone sound (pip).  

 

Y

OUR POOL IS SECURED

7.4  Too much wind 

 

In  some  cases,  while  the  meteorological  conditions  are  too  unfavorable  (strong  wind,  heavy 

rain, thunderstorms …), your falling detector is susceptible to stop its monitoring. The LED 

 :

 

blinks in red. 

D

URING THESE BAD CONDITIONS

,

 YOU SHOULD 

IMPERATIVELY

 INCREASE YOUR WATCHFULNESS

 

 

Содержание TRIT001-US

Страница 1: ...OFF mode 17 7 8 Replacing the batteries 18 7 9 I have an issue with my falling detector 18 8 FAQ Frequently asked questions 20 9 Warranty and after sale services 23 10 Monthly Tests 24 FCC REGULATION...

Страница 2: ...subsurface pool device which detects the fall of an 18 lbs child by providing automatically sounding an alarm This device is not intended to replace any other safety consideration that is adult superv...

Страница 3: ...n unit with a black hose 1 rigid tube with attachment screws 1 remote alarm system 4 1 5V LR20 alkaline batteries supplied 1 AC DC Adapter 110V 12V for the remote system 1 fixing kit screws washers ta...

Страница 4: ...M mode during 20mn max The LED starts to blink in green Immobilize the TRITON TM alongside the edge of the pool with the supplied fixation kit Your device is now operational cf 5 4 UTILISATION All the...

Страница 5: ...totally still Then it goes back to DETECTION mode Be patient because this can take more than 10 minutes to happen NEVER LEAVE THE POOL UNATTENDED IN THIS MODE o In case of high winds the device can t...

Страница 6: ...ODE To reduce your reaction time TRITON includes a remote alarm system with a radio receiver which can be set up near your living room or other convenient location This will also sound a siren in case...

Страница 7: ...N THIS MODE INACTIVE DETECTION LED blinks in red quickly To switch to this mode From the INACTIVE DETECTION mode type the password initially 1234 The siren CAN emits a 85 dB signal at 10 feet when tri...

Страница 8: ...8 Default Signage Default Signage LOW BATTERIES LED blinks in red quickly One low tone sound once in a minute BURP HARDER DEFAULTS the device requires maintenance LED LED LED all the LEDs are blinkin...

Страница 9: ...ng ones are incompatible with falling detector systems The proper performance of TRITON is not correctly achieved if used in parallel with tarpaulins WARNING TRITON is kitted up with a powerful siren...

Страница 10: ...he siren is audible from the inside of your house Your falling detector should be placed in the middle of the largest length on a brink recommended position for rectangular shaped pool If your pool do...

Страница 11: ...ode facultative In this mode the siren is attenuated and stops by itself after 5 seconds See chapter 7 5 page X for more details For these tests TRITON should be in DETECTION mode the LED blinks in gr...

Страница 12: ...d with care to guarantee the waterproofness and the good operating state of your device Check that the 2 main black joints are correctly positioned in their location on the base Put back in place the...

Страница 13: ...te siren you should synchronize the two devices a Choose a location for your remote device o 70 feet away max from the TRITON o Near an electrical plug b Plug the power supply to the remote siren IMAG...

Страница 14: ...mmended to place the siren as high as possible on your wall pay attention to the power supply wire IMAGE 5 o Insert the 2 tapping inserts in the 2 new holes o Screw down the 2 screws through the siren...

Страница 15: ...avoid the formation of algae in the probe In case of restart of your falling detector after an extended stop please proceed the tests explained in 5 4 In case of issue please contact immediately your...

Страница 16: ...oved In that case your device understands your request by responding with a high tone sound PIP but can t restart immediately the monitoring The LED blinks in red It will progressively start the monit...

Страница 17: ...s slowly in yellow and a high tone sound is heard PIP Enter the password change code 1111 the mode will be validated by the LED blinking once in green and a high tone sound PIP Enter your new password...

Страница 18: ...off the TRITON see 7 6 upper Remove with care the 4 caps with the help of a flat screwdriver Unscrew the 4 screws and remove the cover Remove the used batteries Place the new batteries in their locati...

Страница 19: ...e us to give you a quick answer please give us a short description of the problem Please send our technicians your address and a quick drawing of your swimming pool with its dimensions length width de...

Страница 20: ...t substitute for parents watchfulness and or responsible grown up which remains the essential factor for 5 years old children safety It substitutes neither to horse sense nor to individual responsibil...

Страница 21: ...from the pool or alert adults to their presence For more information contact the Association of Pool and Spa Professionals www TheAPSP org This alarm does not replace responsible adult supervision Wh...

Страница 22: ...risk of a cold shock response How to rescue a child from the pool 1 Extend a long object such as a pole shepherd s hook or towel and pull in the child or throw the child a floating object 2 If the ch...

Страница 23: ...r failures resulting from an accident shock negligence or misuse a failure or defect in the electrical supply in an external electrical circuit lightning the use of parts not supplied by ABTYS and una...

Страница 24: ...passed failed 7 Test achieved the 8 Test achieved the Passed failed passed failed 9 Test achieved the 10 Test achieved the Passed failed passed failed 11 Test achieved the 12 Test achieved the Passed...

Отзывы: