13
NOTE:
The control knobs are an integral part of
the cover -
DO NOT
attempt to remove them.
• Lift the cover from the backplate.
• Entry positions for the mains water and
electric cable can be found on
page 6
.
The water inlet
(fig.9)
has been designed to
allow left or right fitting.
To make the inlet either left or right fitting:
• If right entry is required, secure with the
screw included in the screw pack
(fig.9A)
.
• For left inlet, turn the fitting 180°
(fig.9B)
.
• Secure with the screw included in the screw
pack
(fig.9C)
.
NOTE:
The Inlet is not fixed during production.
Deviations from the designated entry points will
invalidate product approvals and could invalidate
product warranty.
INSTALLATION - FITTING THE SHOWER TO THE WALL
WARNING!
Check there are no hidden cables or
pipes before drilling holes for wall
plugs. Use great care when using
power tools near water. The use of
a residual current device (RCD) is
recommended when using power tools.
Fig.9
FITTING THE SHOWER TO THE WALL
A
B
C
Secure inlet with screw.
Secure inlet with screw.
Turn inlet 180° for left entry.