background image

10

OPERATING THE SHOWER - 

(fig.6)

Make sure the commissioning procedure 
has been carried out.

To start the shower

•  Turn the power selector to either 

Cold

Economy

 or 

High

 and the water will flow.

To stop the shower

•  Turn the power selector to the 

OFF

     

position.

•  After stopping, the unit 

MUST

 be isolated via 

the 45amp-isolating switch.

NOTE:

 

If restarting immediately after stopping be 

aware that a slug of hot water will be expelled for 

the first few seconds. 

To use the power selector

The power selector has three ‘

ON

’ positions - 

COLD, ECONOMY

 and 

HIGH

.

Cold setting

 - single blue circle.

•  The cold setting does not provide any heat 

from the heater can to the incoming water.

Economy setting - 

single red circle.

•  Economy uses only one of the elements within 

the heater can.

NOTE:

 

If the stated flow rate required for the unit 

cannot be met due to low water pressure, it will 
be necessary to operate the unit on this setting 
during the warmer months because of flow rate 
limitations entering the unit.

High Setting

 - double red circles.

•  High uses both of the elements within the 

heater can.

IMPORTANT:

 

It will take a few seconds for the 

temperature to stabilise once changes have been 

made.

USER OPERATING INSTRUCTIONS

N-002-A

Note:

 In normal use, it is in order to leave the 

water  supply  permanently  on  to  the  shower 
unit, but as with most electrical appliances,

the  unit  must  be  switched  off  at  the 
isolating switch when not in use.

Power selector

Cold

Economy

High

Temperature 

control

COLDER

Fig.6

OFF

HOTTER

Содержание T70 GSI

Страница 1: ...when not in use This is a safety procedure recommended for all electrical appliances The showerhead and hose supplied with this product are a safety critical part of your shower Failure to use genuin...

Страница 2: ...ing other than those specified This appliance is intended to be permanently connected to the water mains and not connected by a hose set A suitable double pole isolation switch for supply disconnectio...

Страница 3: ...ulations or any particular regulations as specified by Local Water Company or Water Undertakers and should be in accordance with BS EN 806 2 2 The supply pipe must be flushed to clear debris before co...

Страница 4: ...re setting At different times of the year you may have to adjust the position of the temperature control to maintain your desired temperature setting c The stabiliser valve minimises variations in sho...

Страница 5: ...r to the wall 13 15 Plumbing connections 16 Electrical connections 17 Fitting The Cover valve knob positions 18 19 Commissioning procedure 20 Cleaning the filter installers service engineers only 21 F...

Страница 6: ...08mm 108mm 308mm ENTRY POINTS DIMENSIONS WATER Left Bottom Back Top Side Right Bottom Back Side CABLE Left Bottom Back Top Side Right Bottom Back Side Back Back Others Others Inlet connection 15mm dia...

Страница 7: ...the whole installation at the mains supply and remove the correct fuse 3 The shower must be connected to its own independent electrical circuit IT MUST NOT be connected to a ring main spur socket out...

Страница 8: ...ng in a bath or shower cubicle It should be readily accessible to switch off after using the shower 7 Where shower cubicles are located in any rooms other than bathrooms all socket outlets in those ro...

Страница 9: ...es per minute the inlet of the shower for full performance for 8 5Kw 9 5Kw Minimum running pressure and flow to 150kPa 1 5 bar at 11 litres per minute the inlet of the shower for full performance for...

Страница 10: ...he incoming water Economy setting single red circle Economy uses only one of the elements within the heater can NOTE If the stated flow rate required for the unit cannot be met due to low water pressu...

Страница 11: ...ure exceeds the showering safety limit the power to the elements will be removed completely although water will continue to flow When the temperature has cooled sufficiently power to the elements will...

Страница 12: ...espoke hose retainer it will in most cases meet this requirement If the showerhead can still be placed within a bath basin or shower tray within the 25mm limit then a double check valve or similar MUS...

Страница 13: ...the fitting 180 fig 9B Secure with the screw included in the screw pack fig 9C NOTE The Inlet is not fixed during production Deviations from the designated entry points will invalidate product approv...

Страница 14: ...ut positions Decide if top or bottom pipe entry is required Once chosen carefully remove the appropriate cut out using a junior hacksaw and file PLEASE NOTE NONE of the cut outs are designed as snap o...

Страница 15: ...nto position leaving the base of the screw head protruding 6mm out from the wall Hook the backplate over the top screw and fit the bottom fixing screw into position Do not fully tighten the screws at...

Страница 16: ...ss point to the isolator IMPORTANT Before completing the connection of the water supply to the inlet of the shower flush out the pipework to remove all swarf and system debris This can be achieved by...

Страница 17: ...IMPORTANT Fully tighten the terminal block screws and make sure that no cable insulation is trapped under the screws Loose connections can result in cable overheating NOTE The supply cable earth cond...

Страница 18: ...bottom fig 15 2 With the cover off the shower turn the stabiliser valve spindle fully clockwise until resistance is felt fig 16 4 With the cover off the shower turn the temperature control to the 5 O...

Страница 19: ...the OFF position and the temperature control is turned fully clockwise the 5 o clock position Offer the cover to the unit Carefully guide the cover onto the backplate making sure the wires are not tr...

Страница 20: ...s to flow from the flexible hose Slowly turn the temperature control fully anti clockwise fig 20 It will take about thirty seconds for a smooth flow of water to be obtained while air and any debris is...

Страница 21: ...on SWITCH OFF the electricity and water supply at the mains The inlet filter is situated inside the water inlet fitting fig 21 To gain access to the filter remove the cover and bottom trimplate Unscre...

Страница 22: ...ase in ambient water temperature 2 3 1 Readjust flow rate to give increased flow 2 3 2 Select economy power 3 Water temperature cycling hot cool at intervals 3 1 Heater cycling on thermal cut out 3 1...

Страница 23: ...ed while commissioning 6 3 1 Fit new PRD Commission unit with showerhead removed 6 4 Water pressure above specified maximum for unit see rating label 6 3 1 Fit pressure reducing valve to inlet and the...

Страница 24: ...electric products are labelled accordingly with the crossed out wheeled bin symbol This indicates for disposal purposes at end of life that these products must be taken to recognised collection point...

Страница 25: ...TS USED 0 1 2 H O T HOT COLD Turn the main power isolator switch ON Power Knob setting Temperature Knob setting To START the shower turn the power knob from the OFF position to Cold Economy or High 1...

Страница 26: ...26...

Страница 27: ...27...

Страница 28: ...ners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verif...

Отзывы: