t150z pumped thermostatic electric shower
Switch off the electricity supply at the
mains.
Fig.
shows a schematic wiring diagram.
The cable entry points are shown in
fig.
. The
cable can be surface clipped, hidden or via
20 mm conduit.
Note:
Conduit entry can only be from rear.
Route the cable into the shower unit and connect
to the terminal block
(fig.)
as follows:
Earth cable to terminal marked
Neutral cable to terminal marked
N
Live cable to terminal marked
L
Important:
Fully tighten the terminal
block screws and make sure that no cable
insulation is trapped under the screws. Loose
connections can result in cable overheating.
Note:
The supply cable earth conductor must
be sleeved. The outer sheath of the supply cable
must be stripped back to the minimum.
The supply cable must be secured either by
routing through conduit or in trunking or by
embedding in the wall, in accordance with IEE
regulations.
The use of connections within the unit, or other
points in the shower circuit, to supply power to
unspecified equipment other than that listed on
page18, will invalidate the guarantee.
DO NOT
switch on the electricity supply until
the cover has been fitted.
.
Terminal block
.
Earth post
.
Start/stop switch
4.
Cover PCB
5.
Solenoid
6.
10-way ribbon cable
7.
Thermal cut-out
8.
PCB live
9.
PCB neutral
0.
relay
.
relay
.
Power PCB
.
5.25kW
4.
Triac 1
5.
3.25kW
6.
Outlet thermistor
7.
Low flow switch
8.
Pump motor
N-001-A
Note:
The elements on UK models are to 240V
specification and will give a lower kW rating if
the voltage supply is below 240V.
Terminal block
E
L
N
L
N
E
ELECTRICAL CONNECTIONS
WARNING!
After any servicing of the
water supply, always flush out the
pipework to remove any debris.
In these circumstances the unit should
only be re-started by following the
commissioning procedure on page 5-6.
Fig.
Fig.