9
t150z pumped thermostatic electric shower
Note:
The control knobs are an integral part of
the cover –
DO NOT
attempt to remove them.
Unscrew the two top and bottom two retaining
screws
(fig.7)
and lift the cover from the
backplate.
Entry positions for the mains water and electric
cable are from the top, bottom, or from the
back.
Note:
Deviations from the designated entry
points will invalidate product approvals.
If bottom entry has been chosen, fit the
appropriate cut-out in the top of the backplate
(fig.8)
.
If top entry has been chosen, fit the appropriate
cut-out in the bottom of the cover
(fig.9)
.
After choosing the site for the shower, use the
Installation Template supplied to mark the four
fixing holes, the position of which are shown in
(fig.7)
.
Drill and plug the wall.
(An appropriate drill bit should be used. If the
wall is brick, plasterboard or a soft building block,
appropriate wall plugs and screws should be fitted).
Screw the top two fixing screw into position
leaving the base of the screw head protruding
6mm out from the wall.
Hook the backplate over the top of the two screw
and fit the other fixing screws into position.
DO NOT
fully tighten the screws at this stage,
as the fixing holes are elongated to allow for
out of square adjustment after the plumbing
connections have been completed.
FITTING THE SHOWER TO THE WALL
Fig.7
Fig.8
Fig.9