6
t150z pumped thermostatic electric shower
•
The following operation must be
carried out with the flexible hose
screwed to the outlet but without the
showerhead attached. Make sure the
outlet of the flexible hose is directed
to waste.
Turn the Temperature control to number
‘1’ then re enable the power to the isolator
switch. Turn on the isolator switch. The
pump will operate and water will flow from
the shower hose.
Note: The Start/Stop
button will not be connected, the only
way to exit the “commissioning mode”
is to remove power to the PCB.
• Allow the system to run until the water
flows freely without bubbles in it. Turn
the Temperature control knob slowly from
number 1 to the temperature lock out setting
and back again a few times to release any
trapped air.
•
Stop the shower using the isolating
switch.
• Remove the cover, connect the PCB ribbon
cable
(fig.0)
, refit the cover and secure
using all of the retaining screws.
Adjusting the Maximum temperature stop
The temperature control valve has an adjustable
maximum temperature stop mechanism that is
supplied factory set for 47°C *
(This must be set
to 41°C maximum if BEAB Care criteria needs
to be met - REFER To PAGE 30, noTE 1, FoR
APPRoVED PRoCEDURE on TEMPERATURE
TESTInG).
To select a lower or higher maximum
temperature stop setting remove the locking
screw from the mechanism and rotate the
mechanism to the preferred setting point to align
with the screw fixing point. Insert the locking
screw through the temperature setting label and
lock in place
(fig.8)
.
Fig.7
Fig.8
noTE:
*BEAB care mark specification
states a maximum of 41°c.
If the shower is adjusted above the
maximum 41°c the product falls outside
the official BEAB care mark specification.