Operator Manual
Issue 1
TIL – Eng – Spec – 080
Page 47 of 70
SeaHub
7.2. Resetting the Software Default Settings
This procedure describes how to return the software settings (and hence hardware mode’s of the
communication ports) to their factory default values.
DANGER!
Before attempting this procedure ensure that the unit is disconnected from the AC
and DC power source, and all other devices be disconnected from it.
1) Follow the steps described in section 7.1 to open the
housing.
2) Locate switch block “SW1” on the PCB.
3) Using a small screw-driver, pair of tweezers or other small
pointed object to set switch 1 to the “ON” position
NB: Switch 2 will already be in the “ON” position, and should
not be changed.
4) Close the SeaHub housing, and apply power for about 10 seconds. The switch settings are only
read when the SeaHub unit powers up.
5) Disconnect from the power, re-open the housing, and set switch 1 back to the off position. If this
is not done, the unit will not be able to store any new settings.
6) Disconnect from the power again, and fully close up the SeaHub unit, reversing the steps
described in section 7.1.
When reset, the following settings should be restored
Control
Setting
Port Mode A – D
RS232
Panel LED Brightness
15 (Full) and
turned On
ArcNet receive
Source
Analogue
AVR Aux Mode
RAT