Operator Manual
Issue 1
TIL – Eng – Spec – 080
Page 59 of 70
SeaHub
7.9. Firmware & Software Update Procedure
The SeaHub firmware and software can be programmed into the unit using the “Seanet Setup”
application. Future firmware/software updates may become available from
Tritech
to provide expansion of
the unit’s capabilities. Whenever this occurs, the updated firmware and software files will be included
with the installer package for the new version of Seanet Pro software - this will be available for download
from the Support section of the
Tritech
website (
www.tritech.co.uk
).
Whenever this new version of Seanet Pro is installed, the SeaHub Node 252 ‘Status’ in Seanet Setup will
indicate that the unit will require an “Update”. Whenever this happens, follow the procedures below to
update the SeaHub with the new firmware / software changes.
7.9.1. Updating the SeaHub with the new software BinFile
The following procedure describes this…
1) Run the “Seanet Setup” application from the
Windows desktop icon.
2) Ensure the SeaHub Node 252 is detected in the
table. If not, then follow steps in Section 4.3.2 (page
21) which describes setup and configuration of the
SeaHub USB connection and COM port allocation.
3) Once Node 252 is detected, check the ‘Status’
column:
If this appears as “OK” (in Green) then no further
action is required.
If this appears as “Update” (in Red) then continue to
Step 4).
Status = “OK”.
Software up to date - no further action required.
Status = “Update”.
A Software program update is necessary.
Proceed to Step 4).
4) Click on ‘Action’ | ‘Program’ for Node 252. This will
download the new software BinFile into the SeaHub.
5) Click on ‘OK’ to confirm to proceed when requested.
The new program will now be downloaded into the
SeaHub. This may take up to a minute.