Operator Manual
Issue 1
TIL – Eng – Spec – 080
Page 44 of 70
SeaHub
6.5.1. RAT Connection
To connect a RAT terminal through the SeaHub requires the S0756 RAT Extension cable connection
between the RAT and the “PS2 V2-RAT” port on the front of the SeaHub (Cable supplied with the RAT).
6.5.2. RAT Configuration
For the RAT pointer device to function correctly through the module it needs to be a “V2” RAT (i.e. with
Togglestick pointer instead of Trackball) and configured to PS/2. This is as configured on a SeaNet SCU.
However the “older style” SeaKing SCU uses the pointer device set to Serial. Therefore, if your RAT
pointer device fails to operate the following checks must be made.
To open the RAT…
1) Unscrew the four Pozi-drive screws holding the back plate on the RAT.
2) Using a 3mm Allen Key, unscrew the Allen screws through the Brass spacers on the four corners
of the RAT.
3) The Front panel can now be lifted off.
Versa Point wiring for Serial RS232 operation…
Versa Point wiring for PS/2 operation…
NOTE
Ensure the “V2” RAT is configured for PS/2 mode when connected through the
SeaHub. The Serial RS232 mode will not work through the SeaHub.
For further help please contact Tritech Technical Support.