Revision C August 2014
www.trinityhighway.com
36
All rights in copyright reserved
11) Check gaps between Fender Panels. On the bidirectional side of the system, the
maximum gap allowed for these overlapping parts (including Fender Panels overlapping
panels behind the system) is 20 mm [0.78”] for narrow systems (see Figure 30). For
wide systems, the maximum gap allowed is 25 mm [1.0”] (see Figure 33).
If the gaps between the Fender Panels are too large, it may be necessary to replace
bent parts.
12) Replace all crushed Cartridges (see Figures 46, 47, and 48 for proper Cartridge
Placement).
13) Check the torque of all bolts on the system (see table below for torque specifications).
14) Check to be certain that the site is free from any debris. The QuadGuard
®
CEN is once
again ready for use.
Warning:
Anchor Studs….
Torqued to 165 N-m [120 ft-lb]
Shall NOT Protrude Above Nuts
(see Figure 14).
All Other Bolts…
Tightened
Fender Panel….
Maximum Gap Allowed
Narrow Systems
20 mm [.78”]
Wide Systems
25 mm [1.00”]