5.7.39
TMCL™ Control Functions
The following functions are for host control purposes only and are not allowed for stand-alone mode.
In most cases, there is no need for the customer to use one of those
functions (except command 139).
They are mentioned here only for reasons of completeness. These commands have no mnemonics, as they
cannot be used in TMCL™ programs. The Functions are to be used only by the TMCL-IDE to communicate
with the module, for example to download a TMCL™ application into the module.
The only control commands that could be useful for a user host application are:
get firmware revision
(command 136, please note the special reply format of this command,
described at the end of this section)
run application
(command 129)
All other functions can be achieved by using the appropriate functions of the TMCL-IDE.
Instruction
Description
Type
Mot/Bank Value
128 – stop application a running TMCL™ stand-alone
application is stopped
don’t care
don’t care don’t care
129 – run application
TMCL™ execution is started (or
continued)
0 - run from
current address
1 - run from
specified address
don’t care don’t care
starting address
130 – step application only the next command of a
TMCL™ application is executed
don’t care
don’t care don’t care
131 – reset application the program counter is set to
zero, and the stand-alone
application is stopped (when
running or stepped)
don’t care
don’t care don’t care
132 – start download
mode
target command execution is
stopped and all following
commands are transferred to
the TMCL™ memory
don’t care
don’t care starting address of
the application
133 – quit download
mode
target command execution is
resumed
don’t care
don’t care don’t care
134 – read TMCL™
memory
the specified program memory
location is read
don’t care
don’t care <memory address>
135 – get application
status
one of these values is
returned:
0 – stop
1 – run
2 – step
3 – reset
don’t care
don’t care don’t care
136 – get firmware
version
return the module type and
firmware revision either as a
string or in binary format
0 – string
1 – binary
don’t care don’t care
137 – restore factory
settings
reset all settings stored in the
EEPROM
to
their
factory
defaults
This command does not send
back a reply.
don’t care
don’t care must be 1234
138 – reserved
139 – enter ASCII
mode
Enter ASCII command line (see
chapter 5.6)
don’t care
don’t care don’t care