![Trinamic PD57-1060 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/trinamic/pd57-1060/pd57-1060_firmware-manual_1163104024.webp)
PD57/60-1060 / TMCM-1060 TMCL™ Firmware Manual (V1.04 / 2011-AUG-29)
24
Copyright © 2011, TRINAMIC Motion Control GmbH & Co. KG
5.7.3
MST (motor stop)
With this command the motor will be instructed to stop. The command uses the normal acceleration
parameter (soft stop).
Internal function:
The axis parameter
target velocity
is set to zero.
Related commands:
ROL, ROR, SAP, GAP
Mnemonic:
MST 0
Binary representation:
INSTRUCTION NO.
TYPE
MOT/BANK
VALUE
3
don’t care
0
*
don’t care
*motor number is always O as only one motor is involved
Reply in direct mode:
STATUS
VALUE
100 – OK
don’t care
Example:
Stop motor
Mnemonic:
MST 0
Binary:
Byte Index
0
1
2
3
4
5
6
7
8
Function
Target-
address
Instruction
Number
Type
Motor/
Bank
Operand
Byte3
Operand
Byte2
Operand
Byte1
Operand
Byte0
Checksum
Value (hex)
$01
$03
$00
$00
$00
$00
$00
$00
$05